CHAPTER 8: DEBUGGER
160
EPSON
S5U1C63000A MANUAL
(S1C63 FAMILY ASSEMBLER PACKAGE)
Notes
• The a and as commands have the same function.
• The start address you specified must be within the range of the program memory area available with
each microcomputer model.
An error results if the input one is not a hexadecimal number or not a valid symbol.
Error : invalid value
(no such symbol / symbol type error)
An error results if the limit is exceeded.
Error : Address out of range, use 0-0xXXXX
• An error results if the input mnemonic is invalid for S1C63000.
Error : illegal mnemonic
• In guidance mode, the following keyboard inputs have special meaning:
"q
↵
"
… Command is terminated. (finish inputting and start execution)
"^
↵
"
… Return to previous address.
"
↵
"
… Input is skipped. (keep current value)
If the maximum address of program memory is reached and gets a valid input other than "^
↵
", the
command is terminated.
• When the contents of the program memory are modified using the a (as) command, the unassemble
contents of the [Source] window are updated immediately.
• Although the contents of the unassemble display are modified by rewriting code, those of source
display remain unchanged.
GUI utility