S1R72105 Technical Manual
76
EPSON
Rev.1.0
8.4.2.9 Initiator Synchronous Data-in Timing (Data input)
Symbol Specification Min.
Typ.
Max.
Unit
T
235
XSDB0-7, P valid - XSREQ
↓
6.5
-
- ns
T
236
XSREQ
↓
- XSDB0-7, P invalid
5
- - ns
T
237
XSREQ
↓
- XSREQ
↑
11
- - ns
T
238
XSREQ
↑
- XSREQ
↓
11
-
- ns
XSDB0-7,P
XSREQ
T
235
T
236
T
237
T
238