S1R72105 Technical Manual
74
EPSON
Rev.1.0
8.4.2.7 Initiator Asynchronous Data-in Timing (Data input)
Symbol Specification Min.
Typ.
Max.
Unit
T
227
XSDB valid - XSREQ
↓
30
-
- ns
T
228
XSREQ
↓
- XSACK
↓
25
- - ns
T
229
XSACK
↓
- XSDB invalid
0
- - ns
T
230
XSREQ
↑
- XSACK
↑
25
- 90 ns
XSDB0-7,P
XSREQ
XSACK
T
227
T
229
T
228
T
230