13505PLAY Diagnostic Utility
S1D13550
Issue Date: 01/02/02
X23A-B-005-04
Program Messages
WARNING: Did not find a 13505 device.
The HAL was unable to read the revision code register on the S1D13505. Ensure that the S1D13505
hardware is installed and that the hardware platform has been set up correctly.
ERROR: Failed to change to ?? mode.
Could not change to CRT, LCD, or SIMUL mode. This message generally means that the given
hardware/software setup violates the timing limitations described in the S1D13505 Hardware
Functional Specification, document number X23A-A-001-xx.
ERROR: Could not change to ?? bit-per-pixel.
This message generally means that the given hardware/software setup violates the timing limitations
described in the S1D13505 Hardware Functional Specification, document number X23A-A-001-xx.
ERROR: Too many devices registered.
There are too many display devices attached to the HAL. The HAL currently supports only one
device.
ERROR: Could not register S1D13505F00A device.
A S1D13505 device was not found at the configured addresses. Check the configuration address
using the 13505CFG configuration program.
ERROR: Insufficient memory for ?? bit-per-pixel.
The given display resolution requires a larger display buffer than is available to store the image.
Either increase the amount of display buffer or select a lower color depth (bpp).
WARNING: Clocks are too fast for given mode.
This message is only shown if the “m” command was entered and the MCLK/PCLK frequencies
violated the timings in the S1D13505 Hardware Functional Specification, document number X23A-
A-001-xx.