The communications (interface) settings are incorrect.
Scanner’s response:
The lamps turn off and the scanner stops moving.
The scanner stops accepting commands.
Error recovery procedure:
After correcting the communications problem, perform one of the
following.
Turn the scanner off and then back on again.
Press the reset button (if the scanner model has a reset button).
Set the parallel interface’s INIT signal to LOW.
Send a device reset message on your SCSI line.
Set the SCSI’s reset line to active.
System error
The scanner itself is not functioning properly.
Cause:
The lamps are disconnected or burned out.
The shipping screw has not been removed from the carriage (the
scanner cannot perform the carriage initialization procedure).
The scanner is broken.
During scanning, an option error was detected (cover open, paper jam,
etc.).
Scanner’s response:
The lamps turn off and the scanner stops moving.
Command Usage
2-45
Содержание EMP-TW 1000
Страница 4: ...iv ...
Страница 11: ...Introduction Introduction 1 ...
Страница 14: ...4 Introduction ...
Страница 36: ...Halftone mode C None Dither mode A Dither mode B Dither mode C Dither mode D 1 22 Overview ...
Страница 39: ...Chapter 2 Command Usage 2 Command Usage 2 1 ...
Страница 72: ...Color page scanning Use when sending color page data 2 34 Command Usage ...
Страница 95: ...Chapter 3 Command Reference 3 Command Reference 3 1 ...
Страница 118: ... Upper bits beginning with the MSB are valid Lower bits not in use are fixed to 0 3 24 Command Reference ...
Страница 131: ...Parameter range Default value i 00H center Command Reference 3 37 ...
Страница 157: ...Command Reference 3 63 ...
Страница 163: ...Appendix A Interface Specifications A Interface Specifications A 1 ...
Страница 182: ...A 20 Interface Specifications ...
Страница 183: ...Appendix B Scanner Model Technical Data B Scanner Model Technical Data B 1 ...
Страница 268: ...B 86 Scanner Model Technical Data ...