Page 27
EPS Stromversorgung GmbH
Alter Postweg 101 • 86159 Augsburg
Germany
Fon: +49 821 / 570451-0
Fax: +49 821 / 570451-25
www.eps-germany.de
PSI 10000 4U Serie
•
Status display (upper right)
This area displays various status texts and symbols:
Display
Description
The HMI is locked
The HMI is unlocked
Remote:
The device is under remote control from....
Analog
....the built-in analog interface
Ethernet
....the built-in Ethernet interface
USB
& others
....the built-in USB port or a plug in interface module
Local
The device has been locked by the user explicitly against remote control
Alarm:
Alarm condition which has not been acknowledged or still exists.
Event:
A user defined event has occurred which isn’t yet acknowledged.
MS mode: Master (n Sl)
Master-slave mode activated, device is master of n slaves
MS mode: Slave
Master-slave mode activated, device is slave
FG:
Function generator activated, function loaded (only in remote control)
/
Data logging to USB stick active or failed
•
Area for assigning the rotary knobs
The two rotary knobs next to the display screen can be assigned to various functions. This area shows the actual
assignments. These can be changed by tapping this area, as long as it’s not locked. The display changes to:
The physical quantities on the depiction of the knob shows the current
assignment. With a power supply, the left knob is always assigned to the
voltage U, while the right knob can be switched by tapping the depiction.
The area will then show the assignment:
U I
U P
U R
Left rotary knob: voltage
Right rotary knob: current
Left rotary knob: voltage
Right rotary knob: power
Left rotary knob: voltage
Right rotary knob: resistance
The other set values can’t be adjusted via the rotary knobs, unless the assignment is changed. However, values
can be entered directly with a ten-key pad by tapping on the small icon
. Alternatively to the knob depiction,
the assignment can also be changed by tapping the colored set value areas.
1.9.6.2
Rotary knobs
As long as the device is in manual operation, the two rotary knobs are used to adjust set values in the
main screen. For a detailed description of the individual functions see section
.
1.9.6.3
Pushbutton function of the knobs
The rotary knobs also have a pushbutton function which is used in all value adjustment to move the cursor by
rotation as shown: