PSI 10000 4U Serie
3.4.8.3
Log file format
Type: text file in german/european or US american CSV format (depending on the selected setting)
Layout (default german format shown):
Legend:
U set
/
I set / P set / R set
: Set values U, I, P and R
U actual / I actual / P actual / R actual
: Actual values
Output/Input
: State of the DC output
Device mode
: Actual regulation mode (also see
Error
: Device alarms
Time
: Elapsed time since logging start
Important to know:
•
R set and R actual are only recorded if UIR mode is active (refer to section
•
Unlike the logging on PC, every log start here creates a new log file with a counter in the file name, starting
generally with 1, but minding existing files
3.4.8.4
Special notes and limitations
•
Max. log file size (due to FAT32 formatting): 4 GB
•
Max. number of log files in folder HMI_FILES: 1024
•
With setting
Start/stop
being
At DC on/off
, the logging will also stop on alarms or events with action “Alarm”,
because they switch off the DC output
•
With setting
Start/stop
being
Manual
, the device will continue to log even on occurring alarms, so this mode
can be used to determine the period of temporary alarms like OT or PF
3.4.9
The quick menu
The device offers a quick menu which allows for the quick access to often used features and modes being switched
on or off in the
Settings
menu. It can be opened by swiping up from the bottom screen edge or tapping the bar:
Overview: