28
3. Put the throttle to zero (stop) position and press
"SELECT" button. "CAL BA" will be display.
4. Rotate the throttle backward to full power
position and press "SELECT" button, the
display will return to normal and the calibration is
completed.
E50
Charger Fault
If you are not using an ePropulsion charger, please
change an ePropulsion charger. If this condition
persists, please contact your dealer.
E51
Battery
Temperature
Fault
Make sure the environment temperature is within
0°C to 45°C. Charging will continue when cell
temperature is in that range.
E54
Battery Pack
Over Voltage
Stop the motor and wait until the error message
disappears. If the problem persists, contact your
dealer for repair.
E55
Battery Empty
Indicating the battery is empty. The outboard can
probably be restarted at lower speed after the
message is dismissed.
E56
Battery Charging
Over Current
Restart the motor and drive at lower speed. If this
problem still persists, please contact your dealer.
E57
Battery
Discharging Over
Current
Battery can only work between -20°C and 60°C.
Motor can be started again after the battery
temperature is within that range.
E58
Battery
Hardware Fault
Batter y has encountered serious hardware
breakdown. Please replace the battery and contact
your dealer.
E59 Battery Cell Fault
Battery cell fault occurs, please replace the battery
and contact your dealer to repair the problemetic
battery.
Other
Other faults
Please contact your dealer.
Carry out the throttle calibration procedures in strict accordance with the
above sequences.