Owner's Manual for EPILOG Legend Model 6000
December, 2000
Section 15 – Servicing the Legend
75
CONTROLLER
The controller (part #LM1) is located in the controller bay, and is the main electronic component module for
the Legend, see diagram on page 61. To remove and/or service this module, first turn the machine off and
unplug the power cord from the machine or from the wall. Demate the four connectors shown in the diagram
below. Then remove the screws shown in the diagram. The captive screws are inside the machine, and the
four Phillips screws are on the outside. The assembly can now be lifted up and out of the machine. Then
install the replacement. Please be careful to make sure all the connectors are fully seated. Please do not
forget to return the failed component to Epilog.
Connectors
(four)
Captive Screws
(two)
Phillips Screws
(four)