Owner's Manual for EPILOG Legend Model 6000
December, 2000
printer cable to the Legend
. The connector can be connected only one way. Close the wire retainer
clips around the ends of the cable.
2)
Ethernet Port: Because of the unpredictable physical nature of a network, Epilog does not supply a
network cable with the Legend. The Legend uses a 10BaseT style connection. The port is located on
the right side of the machine, near the rear. The network parameters can be set at the Legend, and
details for doing so are in Section 5, “Using the Epilog Legend”.
CONNECTING THE EXHAUST
A contractor prior to the arrival of the Epilog installation technician should install the exhaust system. The
blower should be mounted outside your building for noise considerations. The blower should not be more
than twenty feet from the Legend. You should provide a rigid, smooth duct from the blower to the vicinity of
the Legend. The Legend 32 requires 400 CFM at 6” of static pressure and the Legend 24 requires 400 CFM at
4” of static pressure. Remember to put the blower switch in an obvious and accessible place so it will be
routinely switched on prior to using the engraver. Please connect the blower as shown below.
1)
Locate the exhaust port connector on the rear of the machine. The port is a 6” diameter tube for the
Legend 32 and a 4” diameter tube for the Legend 24. Slip the 6” or 4” flex hose over the port, and
secure with a hose clamp.
LEGEND
BLOWER
ROOF OR
EXTERIOR WALL
Legend 32 - 6” METAL DUCT
Legend 24 - 4” METAL DUCT
Legend 32 - 6” FLEX HOSE
Legend 24 - 4” FLEX HOSE
Section 1 – Getting Started