7
Datasheets
Please find the technical specifications of the ACU, antenna and BUCs in this section.
7.1
ACU
Antenna Control Unit
Dimensions
48 cm x 4.45 cm x 47.8 cm(18.9" x 1.75" x 18.82") (19" Rack 1HU size)
Weight
5.1kg (11.24lbs)
Gyro Interface
NMEA0183 / NMEA 2000 (via RS422 or RS485 or RS232) / SIMRAD
RGC11
Input voltage, frequency
90 ~ 264V AC, 47~63Hz
External I/O
RS232, RS422, Ethernet, USB, GPIO
Local user Interface
OLED display, directional pad, 2 push keys
Modem interface
Ethernet port + serial (optional)
Modem Protocols
openAMIP / SNMP / Telnet / open BMIP
Remote access
TCP / IP
Operating temperature
-20°C to 55°C
Storage temperature
-40°C to 85°C
Humidity
According to IEC 60945
IP class
IP 30
Compass safe distance
0.5m according to IEC 60945
Position acquisition
supplied by ODU
Supported modems
idirect series, Hughes HX200, ViaSat SBT-M, Comtech CDM-250/840,
Gilat Skyedge II C4, Paradise PD25L, Datacom Q-Flex, Spacebridge,
Romantis / Eastar UHP 1000 / UHP 2000, others on request
Cables & connectors
ACU to Antenna
2x Double shielded coax cable (ECOFLEX 10) with N-plugs
ACU to Modem
2x Double shielded coax cable (RG6) with F and TNC-plugs
1x Ethernet patch with RJ45 plugs
ACU to Network
Ethernet patch with RJ45 plugs
7.2
Antenna
DSi6 Ku Pro
DSi9 Ku Pro
DSi13 Ku Pro
Please refer to datasheets, available on our website.
https://www.epak.de/en/support/download-area
Doc ID 0304 03.07.20