background image

 

5

Main circuit wiring

 

 

 

 

 

 

Single phase models input from R/L1, S/L2

AC line input terminals
grounding

UP/DOWN

Function 
Display key
Data 

Confirmation key

RUN/STOP

RS485 
communication 
port

Grounding

Motor connections U/T1, V/T2, W/T3

Motor capacity 
and input power

Frequency

setting knob

LED display

The signal selection

 for AVI to input 

DC0~+10V 

or 4~20 mA

U/T1 V/T2 W/T3

R/L1 S/L2 T/L3

 

Control circuit wiring 

RA RC +10V AVI M0 M1 M2 M3 GND

(1

2

0

V

A

C

/D

C

2

8

V

 3

A

)

Relay

Wire Gauge:22-24AWG

Torque: 4Kgf-cm

M

u

lti

-fu

n

ct

io

n i

n

d

ic

a

tio

n

o

u

tp

u

t c

o

n

ta

c

t

P

o

w

e

r f

o

r s

p

e

e

se

tti

n

g

 

A

n

a

lo

g V

o

lta

g

e

, c

u

rr

e

n

fre

q

u

e

n

cy

 c

o

m

m

a

n

d

M

u

lti

-fu

n

ct

io

n

 a

ss

is

ta

n

t t

e

rm

in

a

l

C

o

m

m

o

n

 s

ig

n

a

l

M

u

lti

-fu

n

ct

io

n i

n

p

u

t s

e

le

c

tio

n 1

M

u

lti

-fu

n

ct

io

n i

n

p

u

t s

e

le

c

tio

n 2

M

u

lti

-fu

n

ct

io

n i

n

p

u

t s

e

le

c

tio

n 3

 

Содержание VFD-L series

Страница 1: ...rive EP ANTRIEBSTECHNIK GmbH Fliederstra e 8 Postfach 1333 63486 Bruchk bel 63480 Bruchk bel Telefon 49 0 6181 9704 0 Telefax 49 0 6181 9704 99 e mail info epa antriebe de www epa antriebe de nderunge...

Страница 2: ...re highly sensitive MOS components on the printed circuit boards These components are especially sensitive to static electricity To avoid damaging these components do not touch the circuit boards with...

Страница 3: ...FD007L21A INPUT 1PH 9 7A 3PH 5 1A 200 240V 50 60Hz OUTPUT 3PH 0 240V 4 2A 1 6kVA 1HP Freq Range 1 0 400Hz MADE IN XXXXX 007L21AT101001 AC Drive Model Input Spec Output Spec Output Freq Range Bar Code...

Страница 4: ...D R E V R U N S T O P P R O G D A T A M O D E R E S E T Do not connect AC power to output WARNING Read the user manual before operation Do not inspect components until LEDs are turned off for at least...

Страница 5: ...rent Motor Multi function indication output contacts Factory default Fault Indication Main circuit power terminals Control circuit terminals Shielded leads If the AC Drive model is VFD002L11A B VFD004...

Страница 6: ...ing knob LED display The signal selection for AVI to input DC0 10V or 4 20 mA U T1 V T2 W T3 R L1 S L2 T L3 Control circuit wiring RA RC 10V AVI M0 M1 M2 M3 GND 120VAC DC28V 3A Relay Wire Gauge 22 24A...

Страница 7: ...s U T1 V T2 and W T3 are connected to the motor terminals U V and W respectively the motor will rotate counterclockwise as viewed from the shaft ends of the motor when a forward operation command is r...

Страница 8: ...alue C 2 Display Process Operation 1 tt 3 Display DC BUS voltage U 4 Display output voltage E 0 a 0 05 User defined coefficient K 0 1 160 1 0 0 06 Software version Read only 0 07 Password input 0 999...

Страница 9: ...Parameters Functions Settings Factory Setting 2 00 Source of frequency command 0 Digital keypad 1 0 10V from AVI 2 4 20mA from AVI 3 Controlled by V R on drive 4 RS 485 communication interface 0 2 01...

Страница 10: ...ters Parameters Functions Settings Factory setting a 4 00 Potentiometer bias freq 0 0 350Hz 0 0 a 4 01 Potentiometer bias polarity 0 positive bias 1 negative bias 0 a 4 02 Potentiometer freq gain 1 20...

Страница 11: ...e program cycle step by step separate by STOP 0 5 04 PLC forward reverse motion 0 15 0 Forward 1 Reverse 0 5 05 Time duration step 0 0 65500 Sec 0 5 06 Time duration step 1 0 65500 Sec 0 5 07 Time dur...

Страница 12: ...exceed during acceleration 10 ocd current exceed during deceleration 11 ocn current exceed during steady state 0 Group 7 Motor Parameters Parameters Functions Settings Factory Setting a 7 00 Motor ra...

Страница 13: ...tion 0 AVR function enable 1 AVR function disable 2 AVR function disable when decel 2 8 16 Dynamic braking voltage 350 450V 380 8 17 DC braking lower bound limit 0 0 400 Hz 0 0 Group 9 Communication P...

Страница 14: ...voltage has exceeded its maximum allowable value 1 Check whether the input voltage falls within the rated AC drive input voltage 2 Check for possible voltage transients 3 Bus over voltage may also be...

Страница 15: ...an not be programmed 1 Switch off power supply 2 Check whether the input voltage falls within the rated AC drive input voltage 3 Switch the AC drive back on Internal memory IC can not be read 1 Check...

Страница 16: ...20mA output impedance 250 multi function inputs1 to 3 3steps JOG UP DOWN command communication setting Operation Setting Keypad Setting by RUN STOP keys Signal External Signal M0 M1 M2 M3 can be combi...

Отзывы: