Dear Customer,

You have bought a high-quality technological 
device which will give you years of pleasure.

Read  the  operating  instructions  before  as-
sembly  carefully  and  keep  both  these  and 
the packaging.

If the device changes hands, please forward 
the instructions with it.

Should  you  still  have  questions  after  read-
ing, our Service Center is happy to help you.

First  check  that  the  device  has  been  deliv-
ered  undamaged.  Please  reclaim  transport 
damages  immediately  with  the  forwarding 
company or contact the company who sup-
plied you with the device.

Important notes

Danger  of  injury  or 

fi re  due  to  incorrect  as-

sembly or usage!

Please  observe  the  following  guidelines  in 
particular!

Electrical installations, repairs and interven-
tions  with  the  device  must  only  be  carried 
out  by  an  electrician.  Unprofessional  inter-
ventions lead to loss of the guarantee claim. 
Incorrect repairs may generate considerable 
risks for the user.

•  Ensure that the voltage information on the 

device  accords  with  the  local  mains  volt-
age.  The  device  is  to  be  connected  to  a 
230 V, 50 Hz protective contact socket.

The  socket  must  remain  accessible  at  all 
times in order to allow quick removal of the 
plug.

CAUTION! The device must be discon-
nected from the mains during all clean-

ing  or  maintenance  work,  when  replacing 
parts  and  accessories  and  when  resolving 
operating malfunctions.

•  This device is not intended to be used by 

people  (including  children)  with  limited 
physical, sensory or cognitive capabilities, 
or  who  have  a  lack  of  experience  and/or 
knowledge,  unless  they  are  being  super-

vised  by  a  person  responsible  for  their 
safety, or receive instructions on how the 
device should be used.

•  Children must be kept away from the lamp 

and  must  be  supervised  to  ensure  that 
they do not play with it.

•  Please  observe  that  the  device  must  not 

be  subjected  to  mechanical  loads  (im-
pacts, pressure, concussions, vibrations). 
The infra-red lamp may break. If the lamp 
breaks,  which  is  improbable  if  the  device 
is used according to its purpose, it must be 
replaced with a new one, and the broken 
one may no longer be used.

CAUTION!  Risk  of  burn  injuries  from 
broken lamps.

•  Quartz lamps are sensitive to substances 

containing  sodium.  Direct  skin  contact 
(contact  with  fi ngers)  reduces  the  lamp 
lifetime and must be avoided.

This  device  is  not  a  medical  product  in 
terms  of  the  MPG  (German  Medical  De-
vice  Law).  The  device  may  not  be  used 
for such purposes.

Содержание IRelax

Страница 1: ...1 GB Print No 29594104en 39 12 IRelax GB Assembly and Operating Instructions...

Страница 2: ...rt No 94 4843 00 6 Assembling the IRelax onto the stand 7 Adjusting the device position 7 Application examples 9 Typical areas of application are 9 Minimum clearances 9 Exposure period 9 Initialisatio...

Страница 3: ...must remain accessible at all times in order to allow quick removal of the plug CAUTION The device must be discon nected from the mains during all clean ing or maintenance work when replacing parts an...

Страница 4: ...ion Risk of burn injuries There is a risk of burn injuries if the device is covered Do not lay cloth ing towels or similar over the device to dry out Defective mains connection lines may only be repla...

Страница 5: ...ut do not tug the inserted foam padding from the device Ensure that the Vitae lamp is not damaged whilst doing so The Vitae lamp is fragile Please be careful when removing the padding Ideally hold the...

Страница 6: ...2 pieces 6 Stand wheels with locking device 2 pieces 7 Stand tube 1 piece 8 Washers 8 5x21 1 piece 9 Nut M 8 1 piece 8 9a optional to position no 8 9 safety cotter pin 1 piece 10 Wing bolt M 8 2 piec...

Страница 7: ...and can be re moved from the slot again if necessary You may required a screwdriver to do this Fig 3 The slot nuts serve as an assembly and po sitioning aid In order to guarantee the spring function...

Страница 8: ...down wards in turned and vertical operating posi tion as the cable must not come into contact with hot device components Caution Only move or adjust the floor lamp in cooled condition Risk of burn inj...

Страница 9: ...ace of the irradiation device be comes hot when used Ensure that you do not come into contact with the device when in operation Exposure period The best results can be obtained with an ir radiation of...

Страница 10: ...con tamination we recommend you take a warm shower afterwards No heat treatments should be carried out in the follow ing cases until you have clarified matters with your doctor Acute and severe inflam...

Страница 11: ...number and model name with detailed description of the fault This guarantee covers defective parts and labour but not the defects caused by wear and tear In case of complaint please return the equipme...

Страница 12: ...ng articles or missing ac cessories He will discuss with you the individual case and try for immediate and customer friendly so lution For economic returns within Germany you will get an RMA number fr...

Отзывы: