background image

16

EN

Default display Stand-by

is shown if the system is in Stand-by mode.
Reset to this display takes place from other 

menu items if no activity is carried out > 15 s.

Default display in operation

is shown if the system is in operation.
Reset to this display takes place from other 

menu items if no activity is carried out > 15 s.

Energy-saving display

If the unit is not used, it will switch af-

ter 15 seconds into energy-saving mode. 

First the background lighting is switched 

off and then a moving time is shown after 

30 minutes, similar to a PC screensaver. 

 

By pressing any key you can return to the 

Stand-by default display.

The following applies for all settings:
The following is shown at the bottom area of 

the display:

12:00

20°C

12:00

20 

min.

20°C

12:00

14:

00

 

12:00

20°C

12:00

20°C

Modifiable value

If the background around a value in the bottom 

part of the display is shown in black, this value 
can be changed using 

  or 

 .

If no key is pressed for >15 s., the unit switches 

back into the default display. Changes made up 

to then are not saved

All settings out of Stand-by are confirmed by 
pressing  

  >3 s and saved in the unit. After 

saving, the changed value will flash twice.

12:34

12:00

14:

35

 

12:00

20°C

12:00

20°C

> 3 s

Cabin lighting switched on

Current cabin temperature

The Clock symbol

Current time

Содержание InfraTec Premium

Страница 1: ...INNOVATIVE SAUNA TECHNOLOGY Made in Germany EOS InfraTec Premium Druck Nr 29344785en 27 21 EN Installation and operating instruction Control unit for infrared cabins...

Страница 2: ...9 Connection diagram for IR radiant heaters 10 Connection diagram for IR heating foils 11 Connection diagram for IR radiant heaters and IR heating foils 12 Connecting the sensor cables 13 Installation...

Страница 3: ...Room temperature for heating foil operation 22 Radiant heater for back 23 Front radiant heater 24 Radiant heater for legs 25 Heating time 26 Switch Off 27 Error messages 28 Recycling 29 Service Addres...

Страница 4: ...stem KTY sensor main sensor cabin temperature KTY sensor heating foil sensor optional Heating time limitation 1 99 minutes 0 12 hours Ambient temperature 10 to 40 C Dimensions control panel HxBxT 130...

Страница 5: ...med by an authorized electrician You must comply with the regulations of your utility company as well as the standard VDE guidelines DINVDE 0100 CAUTION Danger of death never carry out repairs and ins...

Страница 6: ...mm are drilled ac cording to the dimensions shown in Fig 2 2 Insert one of the wood screws into the top center hole The power element is hooked onto this screw Therefore leave the screw out by ca 3 mm...

Страница 7: ...outside the cabin Inside the cabin select a mounting position that is preferably underneath an IR beam Fig 6 Inside wall of cabin Outside wall of cabin Insulation control panel cable Lay the connecti...

Страница 8: ...r output circuits Lay the connection cable from the control ele ment to the power switchgear and produce the plug connections according to the connection diagram Adapting the control to the installed...

Страница 9: ...l arrangement on the circuit board Power unit Installation diagram F1 0 2 AT 6 3 AT 3 3 3 3 3 2 2 Bedienteil Control panel IR Emitter 1 IR Emitter 2 IR Emitter 3 Leistungsteil Relay box optional 230 V...

Страница 10: ...W P3 max 500 W Circuits with dimmable variable power output P1 and P2 Circuit with switchable output P3 IR Emitter 1 Power P1 IR Emitter 2 Power P2 IR Emitter 3 Power P3 230 V AC 50 Hz N N CTR L N L I...

Страница 11: ...T MAINS IR 3 Jumper KTY 10 5 KTY 10 5 L N N N L L S1 S2 Platine JP3 JP2 JP1 IR Emitter 1 Power P1 IR Emitter 2 Power P2 IR Emitter 3 Power P3 IR IR Power load P1 max 1 500 W P2 max 1 500 W P3 max 500...

Страница 12: ...Power P2 IR Emitter 3 Power P3 230 V AC 50 Hz N N CTR L N IR L IR 1 IR 2 L LIGHT MAINS IR 3 Jumper KTY 10 5 KTY 10 5 L N N N L L S1 S2 Platine JP3 JP2 JP1 Power load P1 max 1 500 W P2 max 1 500 W P3 m...

Страница 13: ...uring the unit inspection acc EN 60335 2 53 The room tem perature sensor must always be mounted on the ceiling in the centre of the cabin The fol lowing Figs give you an overview of the instal lation...

Страница 14: ...the heating foil sensor directly onto the heating foil Only mount the heating foil sensor when using IR heating foils with integrated overheat ing protection Mount the sensor directly between the hea...

Страница 15: ...bin into operation The following pages explain the operation settings and options of the Infratec Premium control unit The fig shows the operating unit in Stand by mode with the light switched on Oper...

Страница 16: ...ensaver By pressing any key you can return to the Stand by default display The following applies for all settings The following is shown at the bottom area of the display 12 00 20 C 12 00 20 min 20 C...

Страница 17: ...NL 12 00 20 C 12 00 14 00 12 00 20 C 12 00 20 C 12 00 14 00 12 00 20 C 12 00 20 C 12 00 14 35 12 00 20 C 12 00 20 C 3 sek 12 00 20 C Step 1 connect the device to the mains Step 2 Select and set langua...

Страница 18: ...0 12 00 20 C 12 00 20 C 12 00 14 00 12 00 20 C 12 00 20 C 12 00 DE GB FR ES NL 12 00 20 C 12 00 14 00 12 00 20 C 12 00 20 C 12 00 14 35 12 00 20 C 12 00 20 C Press Set and simultaneously Press Set and...

Страница 19: ...00 20 C 15 sec Press Set for 3 sec onds to confirm To exit press Start or wait 15 sec The display changes back to standby mode 12 00 110 C 12 00 20 C 12 00 20 C 12 00 DE GB FR ES NL 12 00 20 C 12 00...

Страница 20: ...t C F 12 00 20 C 12 00 DE GB FR ES NL 12 00 20 C 12 00 20 C 12 00 20 C F 3 sec 15 sec Switching on the IR system 12 00 20 C Switching off the IR system 20 minutes 12 00 20 min 20 C 12 00 20 min 20 C 1...

Страница 21: ...g operation These changes take effect immediately and are not stored permanently They apply only for the respective session Room temperature In Stand by 12 00 40 C 20 C 12 00 20 C 12 00 55 C 20 C 12 0...

Страница 22: ...s 12 00 20 C IR Room temperature for heat ing foil operation The display shows the temperature value to be regulated in the central area 40 55 C 12 00 20 C In Stand by In operation 12 00 20 min 20 C...

Страница 23: ...eated to max 70 C The room temperature control over the main temperature sensor is disabled in this case 12 00 20 C 5 sek 12 00 20 C 12 00 20 C 12 00 20 C 12 00 20 C In operation 12 00 20 min 20 C 12...

Страница 24: ...12 00 12 00 20 C 15 sec 12 00 20 C Dimmmable only by operation with IR radiators and in combination mode IR radiators heating foils If the power output for IR radiators is reduced in Stand by mode th...

Страница 25: ...by 12 00 20 C 12 00 20 C 12 00 20 C 12 00 20 C In operation 12 00 20 C 12 00 20 C 12 00 20 C 12 00 20 C 15 s 12 00 20 C 12 00 20 min 20 C 5 s 12 00 20 C 12 00 20 min 20 C 15 sek Please note that the...

Страница 26: ...C 12 00 25 min 20 C 12 00 20 C 3 sek In Stand by In operation 12 00 25 min 20 C 12 00 20 C 12 00 25 min 20 C 12 00 20 C 12 00 20 min 20 C 12 00 20 C 12 00 25 min 20 C 12 00 20 C 5 sek 15 sek 12 00 20...

Страница 27: ...I Device switched off completely Position 0 Light enabled Device switched off Position II Switch off The control unit is equipped with a Switch off rocker switch This switch allows to switch the contr...

Страница 28: ...ors and IR heating foils are connected then both sensors are monitored The error messages appear as follows 12 00 20 C SENSOR BREAK 1 12 00 20 C SENSOR SHORT 1 12 00 20 C SENSOR BREAK 2 12 00 20 C SEN...

Страница 29: ...your questions quickly and compe tently please provide the information printed on the type shield including the model item no and serial no in all inquiries Equipment commissioning date ______________...

Страница 30: ...roducts is designed for the ship ping of individually packed goods pallet We expressly point out that our packaging is not suitable for individual shipments via parcel post The manufacturer shall acce...

Отзывы: