Installation
Control panel
The control panel should be mounted outside
the cabin. If the control panel is mounted in-
side the cabin it may not be placed in the direct
range of the IR-beam and the maximum room
temperature may not exceed 60°C. If ductwork
is already provided for electrical installations
then the position of the control panel is prede-
termined by that. The installation is done into
the cabin wall. Please follow the instructions for
installation:
The mounting position must be specified first
for installation outside the cabin.
Inside the cabin select a mounting position
that is preferably underneath an IR-beam.
Fig. 6
Inside wall of cabin
Outside wall
of cabin
Insulation
control panel cable
Lay the connection cable from the control pan-
el to the relay box.
The connection cablemay only be laid between
the insulation and the outside wall of the cabin
(Fig. 7). The insulation must be designed for
max. outside temperature of 75 °C.
Mount the control panel in the wall opening
and fix it with the 4 screws enclosed.
Connection cables
Fastening screws
Finally glue the self-adhesive decorative strips
into the horizontal grooves of the control panel.
Decorative strips
Fig. 8
Fig. 9
Make a wall opening to a size of 105 mm (width)
X 90 mm (height) X 25 mm (min. depth).
105 mm