44
Installation and Operating Instructions - EOS Herkules XL S120
Connections
EN
NOTICE
Damage caused by lime in the water
Water with an elevated lime content, i.e. more than 1.3 millimole
of calcium oxide per litre (hardness class I or hardness levels 1–7 in
Germany), can lead to unit malfunctions.
Install a decalcification system.
NOTICE
Water damage due to operating pressure in the water supply
that is too high
Water can overflow from the container if the water supply con-
nected to the vaporiser has an operating pressure above 6 bar.
This could lead to damage by water.
Ensure that the operating pressure for the connected water
supply is between 2 and 6 bar.
NOTICE
Unit damage due to operating pressure in the water supply
that is too low
Water will not flow fast enough into the container if the water sup-
ply connected to the vaporiser has an operating pressure below
2 bar. This also means that the vaporiser’s heating element is not
completely submersed under water. This can cause damage to the
unit.
Ensure that the operating pressure for the connected water
supply is between 2 and 6 bar.
Necessary steps:
Tools + hardware:
Spanner
Water tap adapter, if needed