34
Installation and Operating Instructions - EOS Herkules XL S120
Connections
EN
4.2 Sauna heater circuit diagrams
For a heater output of up to 24 kW, the heater is connected by two connec-
tion cables. One cable connects the control unit and one connects the out-
put controller (LSG). For a heater output of 30 kW or above, both
connection cables are connected to the output controller. EOS
Herkules XL S120 Vapor with a heater output of 24 kW or above has an
additional connection cable that connects the vaporiser to the relay box.
18 kW heater output
Circuit diagram for 18 kW heater output
1,0 kW
1,0 kW
1,0 kW
1,0 kW
1,0 kW
1,0 kW
1,0 kW
1,0 kW
1,0 kW
1,0 kW
1,0 kW
3
1,0 kW
1,0 kW
1,0 kW
1,0 kW
1,0 kW
1,0 kW
2 1
1,0 kW
5 4 3 2 1
N
V
W
U
9 kW
9 kW
5 4
6
6
2 2 2
N W
1 1
V
1
U
18 kW
A
B
A
To control unit
B
To output controller