EOS Herkules XL S120 - Installation and Operating Instructions
23
Installation
3.2 Installing the temperature sensor in the cabin
WARNING
Risk of fire due to incorrect temperature sensor position
Overheating can occur if the temperature sensor is installed in the
incorrect position; in this case, the sensor may read a lower tem-
perature than actually exists in the cabin. This would trigger the
sauna heater to continue to heat, even though the desired tem-
perature has already been reached.
Install the sensor as shown in the figure (
sions for mounting sensor in cm,
Ignore any contradictory information found in the instructions
for the sauna control unit.
The temperature sensor should be mounted as follows:
above the front longitudinal side of the sauna heater
centred above the rock store, which is not adjacent to the cabin side
wall
Minimum dimensions for mounting sensor in cm
A
Cabin ceiling
D
Cabin rear wall
B
Temperature sensor
E
Rock store (adjacent to the cabin side wall)
C
Cabin side wall
F
Rock store
≥ 125
85
8
~ 51
8
~ 85
≥ 210
96
53
8
A
D
D
C
C
F
E
A
B
B