12
GB
!
ATTENTION!
If a sensor is plugged into the sauna bus
(RJ14 connector), the sensor and the
main board may be irreparably damaged!
Sensorbus
Saunabus
reserviert
Bankfühler
2nd Sensor
humidity sensor
Feuchtefühler
Ofenfühler
Sensor
STB
B
B
B
Connector inside
sensor
Bench sensor
Opening in chip
white
green
brown
Temperature sensor (main sensor)
Humidity sensor (optional)
Bench sensor (optional)
The sensor cable with RJ10 plugs shall be con-
nected to one of three sensor bus RJ10 jacks on
the board. The connection sequence is not im-
portant, you may connect the sensors to any of
the three sensor bus jacks.
The white line of the overheating limiter fuse
shall be connected to the 2-pin connector (STB)
on the main board.
The connected sensors will be automatically
detected and configured.
NOTICE:
The humidity and the bench sensor are option-
al equipment and do not belong to the stand-
ard supply.
If necessary they may be added at a later time
to enhance your sauna capabilities.
Please contact your EOS dealer for further infor-
mation on this and other optional equipment.