EOS EMOTEC B6000 Скачать руководство пользователя страница 4

4

GB

Package contents 

(subject to change)

Included with the control unit are:

1. An heater-sensor board with overheat

shutoff protection, KTY-sensors with
sensor housing , two 3x25 mm
fastening screws  and a 1,7 m long
sensor cable, red and white.

2. A plastic bag with three 4 x 20 mm

fastening screws and three spacer
tubes.

3. A replacement overheat protection

module.

General safety precautions

l

This device has not been designed for

being used by persons (including
children) that are physically or mentally
handicapped or have sensory
disabilities. Moreover, it is not allowed
to use this device without sufficient
experience and/or knowledge, unless
these persons will be supervised by
persons responsible for their security
or in case they have been instructed how
to use this device.

l

 Children are to be supervised in order

to make sure that they do not play with
this device.

l

Attention: It is forbidden to install
the control box in a closed switch

cabinet or behind a wooden panelling!

l

The electrical installation may be
done only by a qualified electrical

technician.

l

You must comply with the regulations of

your power supply company and
applicable VDE regulations (DIN VDE
0100).

l

WARNING:  Never attempt repairs
or installations yourself, as this

could result in serious injury or death.
Only a qualified technician may remove
the housing cover.

l

Please note the dimensions in the

Assembly of the control unit

Wall mounting

Mount the control unit outside the sauna
cabin only.  The most practical mounting
point would be the wall area onto which
the sauna heater is mounted on the inside,
except on the outside of the cabin.  If
electrical conduits are present, mount the
control unit accordingly.  To mount the
control unit, please follow these
instructions:

assembly instructions, especially when
installing the temperature sensor.  The
temperature above the oven is critical for
the temperature setting.  The
temperature can be held within operating
parameters and a minimal temperature
gradient inside the bench area of the
sauna cabin can be achieved only if unit
is assembled correctly.

l

The device may only be used as

intended as a control unit for sauna
heaters up to 9 kW. (Up to 36 kW when
combined with a power control unit)

l

Completely disconnect the control
unit from the electrical circuit, i.e. flip

all circuit breakers or the main circuit
breaker during each installation or repair.

l

Please note the safety and installation

information from the sauna heater
manufacturer.

Содержание EMOTEC B6000

Страница 1: ...1 GB Druck Nr 29342340en 43 06 Installation and user guide EMOTEC B6000 IP x4 GB...

Страница 2: ...sensor 7 Operation 9 Button functions 9 Symbol description 9 Unit initialization 10 Default parameters 11 Temperature indicator 11 Heating time 11 Important notes when programming 12 Heating time lim...

Страница 3: ...sauna bathing Please note the variation in temperatures in the cabin while sauna bathing The hottest area is directly under the cabin ceiling whereas there is a steady temperature gradient towards the...

Страница 4: ...nd applicable VDE regulations DIN VDE 0100 l WARNING Never attempt repairs or installations yourself as this could result in serious injury or death Only a qualified technician may remove the housing...

Страница 5: ...0 cm eye level ca 34 cm 19 cm eye level 17 4 cm 3 3 Illust 3 3 Illust 3 2 3 Hang the control unit onto the 3 mm projecting screw Insert the included rubber sleeves into the openings on the back side o...

Страница 6: ...manufacturer in front of the air intake opening Lead the silicon lines through the electrical conduits to their respective terminals on the control unit and connect them according to the circuit diag...

Страница 7: ...You should not install sensor and power supply lines together or lead them through the same conduit This can lead to interferences in the electronics such as fluttering in the relays If it is absolut...

Страница 8: ...rt circuits To do this release one of the white lines in the sensor housing The safety relay of the control unit should now fall i e the heating circuit should now be interrupted Illust 10 Sensor whit...

Страница 9: ...st 11 Button Functions Mode Operation Symbol description Time F1 P1 Pre selected time P2 Heating time P3 Heating dry P4 Ventilation function Operating switch on off Lamp on off Program button Selectio...

Страница 10: ...programming You may now set the current time using the and buttons during the blinking of the clock symbol To accept the selected time press the MODE button until the selected time begins to blink Bri...

Страница 11: ...r displays the pre selected temperature The colored area of the thermometer displays the current temperature in the cabin During the heating cycle the thermometer rises to the preset temperature Once...

Страница 12: ...ll default back to standard and the illumination will cease after a short time If you wish to individually set the heating time for your sauna system press the MODE button and choose P2 using the sele...

Страница 13: ...ter press the MODE button P1 then appears on the display in the programming area Press the button repeatedly until P3 and the heating symbol appear on the display and confirm this with the MODE button...

Страница 14: ...r though that the cabin needs 40 50 minutes for warming up to create a pleasant climate in the cabin For example if you wish to take your sauna bath at 6 p m then you should set the startup time to 5...

Страница 15: ...nd the previously set time begins to blink with the clock symbol Set the current time using the and buttons e g when adjusting daylight savings time Confirm your selection by pressing and holding the...

Страница 16: ...may use a 100 mA T type fuse for replacement In case of breakdown press the control unit switch on the left part of the rocker to the first position switch position 0 The unit is now completely switc...

Страница 17: ...0 to 115 C Sensor system KTY Sensor with overheat shutoff protection at 139 C Control characteristics digital two step control of 20 C max cab temperature Fan capacity max 100 W max 450 mA only fan wi...

Страница 18: ...ram Sauna control unit EMOTEC B6000 AC 400 V 3N P max 9 0 kW U V W N N L1 L2 L3 light S1 S2 400 V 3N AC 50 Hz fan w KTY 11 5 139 C r r w U V W N N N L1 L2 L3 S1 light fan DC 12 V 24 V limiter sensor p...

Страница 19: ...warranty In the event of a claim please indicate the serial number as well as the article code number and type name with expressive description of the fault This warrenty covers damaged parts but no...

Отзывы: