EOS EMOTEC B6000 Скачать руководство пользователя страница 3

3

GB

Dear customer,

with purchase of this sauna control unit you
opted for a superior quality, high-tech
electronic device which was developed and
manufactured according to the highest
standards and guidelines.

Please note that an optimal interaction of
sauna cabin, sauna heater and sauna
control unit is mandatory for a pleasant
sauna climate in your cabin.

With this superior sauna control unit you
can "operate" your sauna system, and
thanks to the many individual
programming settings you will surely soon
find the setting that suits you best.

Perception in the sauna is very subjective,
therefore it really requires your own
perception, or that of your family to find the
most suitable settings.

By default the finnish sauna is preset to
95°C.

The following operation instructions
describe how to pre-select "your" climate
in the cabin. Read these instructions
carefully, so that you quickly and easily find
your way though the programming process.

General information concerning sauna bathing

Please note the variation in temperatures
in the cabin while sauna bathing. The
hottest area is directly under the cabin
ceiling, whereas there is a steady
temperature gradient towards the floor of
the cabin. Inversely, the relative humidity is
lowest directly under the cabin ceiling and
the highest on the cabin floor.

For safety reasons the temperature sensor
with the overheat safety shutdown is located
on the cabin ceiling above the heater , since
this is the hottest area in the cabin.

Therefore there will always be temperature
variations between the temperature sensor
of the control unit and the thermometer in
the cabin.

For example, when pre-setting the cabin
temperature to 100°C, the thermometer
inside the cabin may easily show 85°C -
90°C. This complies with the typical climate
inside the cabin.

Always observe hygiene. Always use hand-
or bathing towels, to avoid getting
perspiration on the wood.

To avoid the perception of draft, you should
avoid using any ventilation system while
sauna bathing. It should only be used if
recommended by the cabin manufacturer.

Always make sure no objects are
located on the sauna heater before

starting the heating cycle.

Содержание EMOTEC B6000

Страница 1: ...1 GB Druck Nr 29342340en 43 06 Installation and user guide EMOTEC B6000 IP x4 GB...

Страница 2: ...sensor 7 Operation 9 Button functions 9 Symbol description 9 Unit initialization 10 Default parameters 11 Temperature indicator 11 Heating time 11 Important notes when programming 12 Heating time lim...

Страница 3: ...sauna bathing Please note the variation in temperatures in the cabin while sauna bathing The hottest area is directly under the cabin ceiling whereas there is a steady temperature gradient towards the...

Страница 4: ...nd applicable VDE regulations DIN VDE 0100 l WARNING Never attempt repairs or installations yourself as this could result in serious injury or death Only a qualified technician may remove the housing...

Страница 5: ...0 cm eye level ca 34 cm 19 cm eye level 17 4 cm 3 3 Illust 3 3 Illust 3 2 3 Hang the control unit onto the 3 mm projecting screw Insert the included rubber sleeves into the openings on the back side o...

Страница 6: ...manufacturer in front of the air intake opening Lead the silicon lines through the electrical conduits to their respective terminals on the control unit and connect them according to the circuit diag...

Страница 7: ...You should not install sensor and power supply lines together or lead them through the same conduit This can lead to interferences in the electronics such as fluttering in the relays If it is absolut...

Страница 8: ...rt circuits To do this release one of the white lines in the sensor housing The safety relay of the control unit should now fall i e the heating circuit should now be interrupted Illust 10 Sensor whit...

Страница 9: ...st 11 Button Functions Mode Operation Symbol description Time F1 P1 Pre selected time P2 Heating time P3 Heating dry P4 Ventilation function Operating switch on off Lamp on off Program button Selectio...

Страница 10: ...programming You may now set the current time using the and buttons during the blinking of the clock symbol To accept the selected time press the MODE button until the selected time begins to blink Bri...

Страница 11: ...r displays the pre selected temperature The colored area of the thermometer displays the current temperature in the cabin During the heating cycle the thermometer rises to the preset temperature Once...

Страница 12: ...ll default back to standard and the illumination will cease after a short time If you wish to individually set the heating time for your sauna system press the MODE button and choose P2 using the sele...

Страница 13: ...ter press the MODE button P1 then appears on the display in the programming area Press the button repeatedly until P3 and the heating symbol appear on the display and confirm this with the MODE button...

Страница 14: ...r though that the cabin needs 40 50 minutes for warming up to create a pleasant climate in the cabin For example if you wish to take your sauna bath at 6 p m then you should set the startup time to 5...

Страница 15: ...nd the previously set time begins to blink with the clock symbol Set the current time using the and buttons e g when adjusting daylight savings time Confirm your selection by pressing and holding the...

Страница 16: ...may use a 100 mA T type fuse for replacement In case of breakdown press the control unit switch on the left part of the rocker to the first position switch position 0 The unit is now completely switc...

Страница 17: ...0 to 115 C Sensor system KTY Sensor with overheat shutoff protection at 139 C Control characteristics digital two step control of 20 C max cab temperature Fan capacity max 100 W max 450 mA only fan wi...

Страница 18: ...ram Sauna control unit EMOTEC B6000 AC 400 V 3N P max 9 0 kW U V W N N L1 L2 L3 light S1 S2 400 V 3N AC 50 Hz fan w KTY 11 5 139 C r r w U V W N N N L1 L2 L3 S1 light fan DC 12 V 24 V limiter sensor p...

Страница 19: ...warranty In the event of a claim please indicate the serial number as well as the article code number and type name with expressive description of the fault This warrenty covers damaged parts but no...

Отзывы: