Programming fan operation
This control unit lets you operate a fan.
By factory default, "no fan operation" is
specified.
To program the fan function, first press the
"MODE" button to reach the programming
mode.
P1 then appears on the display.
P 1
P 4
without symbol
= no fan operation
with symbol
= fan operation
Programming current time
To reach this program level, press the
"MODE" button and the
button simul-
taneously until F1 is displayed, as well as
the clock symbol.
You can change the time with function F1.
Confirm with the "MODE" button and the
previously set time begins to blink with the
clock symbol.
Set the current time using the
and
buttons (e.g. when adjusting daylight-
savings time).
Confirm your selection by pressing and
holding the "MODE" button, until the
entered value begins to blink.
F1 briefly appears on the display, then the
unit returns to its default readout.
Press the
button repeatedly to reach
the program level P4. The fan symbol
appears on the display.
Confirm by pressing the "MODE" button.
A "0" appears on the display (no fan
operation). By pressing the
button, you
can set a "1" (fan operation).
Confirm your selection by pressing the
"MODE"
..
button. On the display appears
shortly P4, then the unit returns to its default
readout and in set value "1" the fan symbol
appears on the display.