INSTALLATION
AFTER THE WALL IS FINISHED ...
MOUNTING THE SENSOR PLATE
The stainless steel sensor unit is always mounted
flush to the wall. Feed the power pack cable
through the conduit and make the connection
to the sensor by joining the line plug and socket,
observing the polarity of the plug.
Connect flexible inlet hose for the spout to
solenoid again, turn on water and test for leaks.
Test the tap again for correct operation.
Important:
Before fixing the plate in place, apply a bead of
silicon sealant across the top of the plate and
down the sides to prevent moisture getting
between the wall face and the plate.
Fix the sensor panel using four screws provided.
Take care not to put hands in front of the lens
when mounting the plate, as the tap is now
operational and will activate.
TESTING
Turn on the power to the unit and test the unit.
Wave-On Wave-Off Model: Wave the back of
your hand through the beam to turn the water
on, and again to turn the water off.
Time-Flow: Simply place your hand in front of
sensor, and activate the sensor.
For more details on sensor functions, refer to
“Sensor Program”.
WARNING:
Sensor components are fragile and
sensitive. Do not force the sensor
plate to fit onto wall, or attempt to
disassemble sensor components, as this
could result in damage to sensor.
TESTING
Turn the water on, and check for leaks.
Connect all electrical components together temporarily, turn the power on and test the tap.
Once correct operation of the tap is confirmed, disconnect the sensor plate cable and turn off the
power to the transformer. Turn water off at the isolation valve and disconnect the spout & sensor
plate. The tap is now ready for sheeting or finishing of the wall.