10
Call 1300 369 273
www.enware.com.au
TROUBLESHOOTING
Sensor - Stainless Steel Face Plate and Sensor Time-Flow (6 Sec Default) suit ENM5071)
ENMS134
Sensor - Stainless Steel Face Plate and Sensor Wave-On-Wave-Off (suit ENM5072)
ENMS133
Solenoid 1/2”
EMS804
Transformer Input 240V output 24V 1 Amp with 2m Lead
EMS805
2m Extension Cable (transformer to sensor)
EMS840
4m Extension Cable (transformer to sensor)
EMS841
4m Solenoid Extension Lead (Sensor to Solenoid) – Spade connections
EMS813
Solenoid service kit (1/2” AC)
ENMS229
Spout Aerator (8 Lpm, Standard M22 -1)
SP301
Fixing screw for sensor plate (Security M4x25 CSK Screw)
672480
Spout base O-ring (BS 119)
672352
“-205” Spout Only
SPC203
“-250” Spout Only
SPC250
SPARE PARTS
PROBLEM
CAUSE
RECTIFICATION
Tap/Water continues to flow
when power to tap (power
point) is both off or on
Solenoid valve is installed the wrong
way round. Check the direction of
water flow is with arrow
Re install valve correctly
Debris in solenoid valve
Port hole in solenoid diaphragm is
blocked
Take solenoid apart and clean debris
from plunger or diaphragm
Solenoid diaphragm is damaged
Replace solenoid diaphragm with
service kit
Warer supply pressure is too low
check dynamic water pressure is at
least 100 kPa
Tap/Water turns on by itself
Sensor is picking up reflections or
movement
Relocate sensor away from object/
movement
Tap/Water continues to flow
but only when power is on
Sensor is damaged by water or
incorrect cleaning
Replace sensor and rectify sealing
or cleaning methods
Tap/Water does not turn on
when hand is waved in front of
sensor.
Water supply is off or Thermostatic
mixing valve has shut down
Check water supply and TMV
Solenoid valve is damaged
Replace solenoid valve
Power supply is off or Power pack is
damaged
Turn power on or replace power
pack
Sensor is damaged
Replace sensor
Water only turns on sometimes
Sensor has become
de-sensitised
Replace sensor
Sensor activates randomly
Faulty or flickering lighting is
interfering with sensor beam
Repair faulty or flickering light