INSTALLATION
BEFORE PROCEEDING WITH INSTALLATION
SELECT THE LOCATION OF THE SENSOR
When selecting a location to install the
wall-mounted sensor, consider the following:
• Ease of operation
• Water splash / water drips
• Passing traffic
Be sure that passing traffic cannot trigger
the sensor. Allow at least 400mm clearance
between sensor and passing traffic.
• Obstructions
Ensure that nothing is within range of the
sensor. Any obstruction directly in front of, and
within possible range of, the sensor can trigger
the sensor randomly or constantly turn it on.
• Reflections and Lighting
If the sensor unit is installed into a location
where a nearby wall or object is reflecting
the Infrared light back, the unit is effectively
blinded and will not operate. Up to 600mm
clearance may be necessary from reflective
surfaces, such as ceramic tiles and stainless
steel, directly in front of, and parallel to, the
front face of the sensor. Any bright lighting
reflecting off a highly reflective surface such
as a stainless steel sink, or a high visibility
reflective vest, may also interfere with correct
sensor operation.
SET-OUT HEIGHTS
Suggested heights from finished floor:
Spout Oulet
1050 mm
1120mm to point of water
discharge
(Australasian Health Facility
Guidelines)
Top of
Basin
850 mm
865mm (Australasian Health
Facility Guidelines)
800 - 830mm
(refrerence: AS1428.1-2009)