Maintenance
Filter Replacement
Filters should be replaced at least annually, or more regularly dependent on environmental
conditions. The status indicator will indicate filter change required in line with the filter change
interval setting. Replacement filters are available from EnviroVent.
G4 Filter Set
2 framed filters
FILTER-G4-ES500
Status Indicator Filter Notification Reset
Ensure the unit is powered up. To clear the
status indicator filter notification press &
hold the reset switch with a ball point pen
or similar object for 10 seconds. The switch
is located behind the small hole in the
front of the status indicator. All lights will
momentarily be illuminated indicating a
successful reset.
1. Remove front cover, see page14.
2. Slide out filters fitted either side of heat
exchanger as shown.
3. Replace filters by carefully sliding the
replacement filters either side of the heat
exchanger.
4. Ensure arrows printed on the ends of the
Filters point towards the heat exchanger.
Units use unequal length filters. When
replacing filters ensure the short filter is
fitted to the right hand side of the heat
exchanger, see illustration.
5. Replace the front cover. When refitting
front cover do not overtighten screws.