background image

7

 

energiSava

®

 500

SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING 
THIS UNIT, CALL US ON: 

0345 27 27 810

Controls & Features

The following describes the controls and features of the energiSava

®

 500. Ensure the supplied 

control is adequately labelled, indicating function clearly.

The unit can be controlled by various volt free 

switches and sensors. Ensure all controls are 

adequately labelled, indicating their function clearly.

Filter Covers

The filters are located behind a removable cover 

on the front of the unit.

Continuous Speed

Continuous speed is the normal continuous 

extract and supply air flow running speed of the 

units.

Auto Setback Speed

Setback speed is used to reduce ventilation rates. 

Setback speed is automatically set at the mid 

point between minimum possible continuous 

speed and the selected continuous speed. The 

setback speed can be enabled by connection of 

a volt free one-way switch.

Boost Speed with Overrun Timer

Boost speed increases the extract and supply 

air flow. Boost speed is configured with step-

less independent fan controls and includes an 

overrun timer variable between 0 and 60 minutes. 

The boost speed can be triggered by any device 

which provides a volt free one-way switch, such 

as a PIR, thermostat, humidistat or a standard 

one-way switch.

If the unit is left in boost (latching switch) for 

longer than 2 hours the overrun timer is disabled 

meaning the unit will return to continuous speed 

as soon as the switch holding the unit in boost 

is released.

Status Indicator (included as standard)

The status indicator is a low voltage hard wired 

remote LED ventilation information panel, to fit a 

standard UK patress or recessed backbox. The 

indicator has six LEDs which display:

• Normal 

Solid Light - 

Unit is running at continuous speed. 

Flashing light - 

Unit is running at setback speed.

• Frost 

Unit is in automatic frost protection mode.

• Filter 

Filters require change.

• Boost 

Solid light - Unit is running at boost speed. 

Flashing light boost alert is active.

• Summer 

Unit is in summer bypass.

• Fault 

Unit has a fault - Contact the installer.

Product Overview

Содержание energiSava 500

Страница 1: ...energiSava 500 INSTALLATION GUIDE FOR ENGINEER INSTALLER...

Страница 2: ...24AWG Stranded Tinned Copper 11 Control communication cables should not be placed within 50mm or on the same metal cable tray as any 230V lighting or power cables 12 Ensure all cable glands are fully...

Страница 3: ...f should be insulated or a condensate trap should be fitted just below roof level 5 Ducts within the building heated envelope between the external terminals and the unit sFromAtmosphereandToAtmosphere...

Страница 4: ...Auto Setback Speed 7 Continuous Speed 7 Boost Speed with Overrun Timer 7 Status Indicator Boost Alert 8 Summer Bypass 8 Summer Kick Up Mode 8 Automatic Frost Protection 8 Integrated Humidity Sensor 8...

Страница 5: ...efore being ducted to the outside Fresh air is drawn into the unit from outside which is warmed by the heat exchange cell and delivered into the living dining and bedroom areas Packaging Contents Insp...

Страница 6: ...difficult for maintenance and repair The unit MUST be mounted level front to back and side to side 1 Mark a horizontal line on the wall using a spirit level This line will be approximately 330mm below...

Страница 7: ...nsuring it is pushed over the lip and aligned with a screwdriver access hole to enable tightening of the hose clamp 2 Insert 22mm O D PVC pipe into condensate drain socket up to the stop no more than...

Страница 8: ...t speed increases the extract and supply air flow Boost speed is configured with step less independent fan controls and includes an overrun timer variable between 0 and 60 minutes The boost speed can...

Страница 9: ...ink wire will enable summer kick up mode When summer kick up mode is trigged by summer bypass the increased fan speed can be prevented either manually or automatically Manual This is by means of a vol...

Страница 10: ...and Controls Status Indicator Mains cable must be separate from the communication cables See Important Information Supply wiring diagram 230V Connection at indicator Connection at unit L N 12V A B 0V...

Страница 11: ...HR There is maximum of 10 single pole switches or humidistats that can be used To Boost using switch live a relay is required SWHT BOXRELAY Momentary Boost switch SWHT BOOST M Volt free setback switch...

Страница 12: ...inuous speed and boost speed are programmed by placing the controller into program mode via the program run switch and changing the position of the rotary potentiometers When applying power for the fi...

Страница 13: ...n program run switch to centre position to exit commissioning For the commissioning settings to be stored the unit needs to be powered up Continuous Supply Extract Speeds Move program run switch to co...

Страница 14: ...from the run position to the continuous position from the continuous position to the boost position and back to the run position To ensure that the reset switch movements are registered by the control...

Страница 15: ...or best results 1 Slide out filters fitted either side of heat exchanger 2 Carefully remove any dust from face of heat exchanger interior of the unit and the bypass using a vacuum cleaner Do not use w...

Страница 16: ...tion press hold the reset switch with a ball point pen or similar object for 10 seconds The switch is located behind the small hole in the front of the status indicator All lights will momentarily be...

Страница 17: ...out charges may apply if a fault cannot be identified Supply Only If your product has been supplied by EnviroVent and installed by a third party it is covered by a two year parts only warranty If you...

Страница 18: ...17 energiSava 500 SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT CALL US ON 0345 27 27 810 Serviced By Company Date Notes Service Record...

Страница 19: ...it or the package indicates that disposal of this unit after its lifecycle could harm the environment Do not dispose the unit as unsorted municipal waste it should be disposed by a specialized company...

Страница 20: ...read carefully to ensure simple installation and a long trouble free life for the user Delivering innovative and sustainable ventilation solutions worldwide EnviroVent Ltd EnviroVent House Hornbeam B...

Отзывы: