background image

2

FOR SAFE INSTALLATION AND OPERATION OF YOUR “ENVIRO” HEATER, 

PLEASE CAREFULLY READ THE FOLLOWING INFORMATION:

•  All ENVIRO gas-fired appliances must be installed 

in accordance with their instructions. Carefully read all 

the instructions in this manual first. Consult the building 

authority having jurisdiction to determine the need for 

a permit prior to commencing the installation.
•   

NOTE:

  Failure  to  follow  these  instructions  could 

cause  a  malfunction  of  the  fireplace,  which  could 

result in death, serious bodily injury, and/or property 

damage.
•  Failure to follow these instructions may also void 

your fire insurance and/or warranty.

GENERAL

•  Installation  and  repair  should  be  done  by  a 

qualified  service  person.  The  appliance  should  be 

inspected before the first use and, at least, annually 

by  a  qualified  service  person.  More  frequent 

cleaning  may  be  required  due  to  excessive  lint  from 

carpeting, bedding material, etc.  It is imperative the 

control  compartments,  burners  and  circulating  air 

passageways of the appliance be kept clean.
•  Due  to  high  temperatures,  the  appliance  should 

be  located  out  of  high  traffic  areas  and  away  from 

furniture and draperies.

Children  and  adults  should  be  alerted  to  the 

hazards  of  high  surface  temperatures  and 

should  stay  away  to  avoid  burn  or  clothing 

ignition.

•  Young  children  should  be  carefully  supervised 

when in the same room as the appliance.
•  Clothing or other flammable materials should not 

be placed on or near the appliance.

FOR YOUR SAFETY

•  Installation and service must be performed by a 

qualified installer, service agency or gas supplier.
•  This installation must conform to local codes or, in 

the absence of local codes, to the current CAN/CGA-

B149 installation code (Canada) or National Fuel Gas 

Code ANSI Z223.1.2 (USA)

•  To  prevent  injury,  do  not  allow  anyone  who  is 

unfamiliar with the stove to operate it.

 

To  prevent  injury,  if  the  pilot  or  pilot  and 

burners have gone out on their own, open the 

glass door and wait 5 minutes to air out before 

attempting to re-light the stove.

•  Always  keep  the  area  around  these  appliances 

clear  of  combustible  material,  gasoline  and  other 

flammable liquids and vapours.
•  These appliances should not be used as a drying 

rack for clothing or for hanging Christmas stockings/

decorations.
•  Due to the paint curing on the stove, a faint odor 

and  slight  smoking  will  likely  be  noticed  when  the 

stove is first used.  Open a window until the smoking 

stops.
Always connect this gas stove to a vent system and 

vent  to  the  outside  of  the  building  envelope.  Never 

vent to another room or inside the building. Make sure 

the specified vent pipe is used, properly sized and of 

adequate  height  to  provide  sufficient  draft.    Inspect 

the venting system annually for blockage and signs of 

deterioration.

WARNING: 

Failure to position the parts in accordance 

with the diagrams in this booklet, or failure to use only 

parts  specifically  approved  with  this  appliance,  may 

result in property damage or personal injury.

WARNING: 

Do  not  operate  with  the  glass  front 

removed,  cracked  or  broken.    Replacement  of  the 

glass should be done by a licensed or qualified service 

person.
•  Never  use  solid  fuels  such  as  wood,  paper, 

cardboard, coal, or any flammable liquids, etc., in this 

appliance.
•  Do not use this heater if any part has been under 

water. Immediately call a qualified service technician 

to inspect the heater and to replace any part of the 

control or gas control systems that have been under 

water.
•  Do not abuse the glass by striking it or slamming 

the door shut.

Safety Precautions

Содержание retreat

Страница 1: ...ow the gas supplier s instructions If you cannot reach your gas supplier call the fire department WARNING If the information in this manual is not followed exactly a fire or explosion may result causi...

Страница 2: ...to the current CAN CGA B149 installation code Canada or National Fuel Gas Code ANSI Z223 1 2 USA To prevent injury do not allow anyone who is unfamiliar with the stove to operate it To prevent injury...

Страница 3: ...ming Mount Brackets 15 Wall Finishes 16 Mantel Clearances 17 Vent Termination Restrictions 18 Fireplace Horizontal Vent Kit 50 1235 19 Other Approved Vent Parts 20 Venting 22 Vent Configurations and R...

Страница 4: ...treat Fireplace Has been certified for use with either natural or propane gases See rating label Is not for use with solid fuels Is approved for bedroom or bed sitting room IN CANADA must be installed...

Страница 5: ...s Line Access 811 16 220mm 1 11 16 42mm Gas Line Access Electrical Access 1 5 8 41mm 81 2 215mm 63 16 158mm 43 1093mm 37 8 98mm 59 16 141mm 4111 16 1059mm 5 Specifications INSTALLATION OPTIONS Paralle...

Страница 6: ...Immediately call your gas supplier from a neighbors phone Follow the gas suppliers instructions If you cannot reach your gas supplier call the fire department C Use only your hand to push in or turn t...

Страница 7: ...Less Air Air Shutter the fireplace is getting too much air Therefore the air shutter should be closed moved right slightly until the correct flames are achieved Flames that are very orange with tall...

Страница 8: ...fireplace glass cleaner available at your local Enviro dealer See MAINTENANCE AND SERVICE GLASS DOOR REMOVAL and MAINTENANCE AND SERVICE CLEANING THE GLASS REMOTE CONTROLS This fireplace can use an op...

Страница 9: ...rs will damage the glass and plated surfaces Depending on the amount of use the glass should require cleaning no more than two or three times a season In some instances a white film may form on the gl...

Страница 10: ...t use other cleaners as they may leave a residue which can become permanently etched into the surface GLASS DOOR REMOVAL In order to install the log set and for regular cleaning the glass door must be...

Страница 11: ...conversion kit Simply screw the new injector inside the pilot hood using the Allen key and reinstall the hood by placing the hood on the assembly line up the key way and snap into place Step 7 Remove...

Страница 12: ...o Please carefully read the safety precautions at the front of this manual Warning Clearances must be sufficient to allow access for maintenance and service VENT HEAT SHIELD SET UP The vent shield mus...

Страница 13: ...ensions shown in Figure 12 and Table 2 Refer to Figure 1 and Table 3 for the placement of the gas and electrical inlets When the basic framing is done and the unit is installed the three 3 top pieces...

Страница 14: ...en though the Retreat can be installed at floor level without a hearth there are a few options with raised fireplaces raised with a raised hearth Figure 15 raised with a floor level hearth Figure 16 o...

Страница 15: ...ce with Raised Hearth 431 2 110 5cm minimum to ceiling Figure 17 Raised Fireplace with No Hearth The Retreat can be secured to the framing and the flooring At either side of the top there are two 2 br...

Страница 16: ...mple drywall and tile see Figure 20 21 The wall may be finished up to the fireplace standoffs with combustible materials This facing style should tuck under the bottom edge at the front bottom of the...

Страница 17: ...bove the unit the clearance is 8 203mm above the elbow A shelf may be installed above the unit We recommend that no heat sensitive items or components be placed on the shelf see Figure 24 MANTEL CLEAR...

Страница 18: ...12 in 30 cm Clearance from permanently closed window to prevent condensation D 24 in 60 cm Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 ft 60 c...

Страница 19: ...e exterior wall Using this center point scribe a 10 25 4 cm hole or square on the wall Cut the hole from the interior through the exterior wall surfaces Please read and understand these instructions b...

Страница 20: ...on the intake collar of the vent terminal slide the 65 8 16 25 cm flex intake liner over the collar secure the flex liner with three 3 sheet metal screws evenly spaced 14 Attach the vent terminal to t...

Страница 21: ...black 990 4DT EL90 SV4EBR90 4D90B 90 elbow black 950 4DT VS SV4VS Vinyl siding standoff sheild 942 4DT WT SV4RSN 4DWT Wall thimble 953 4DT SC SV4FC 4DSC Storm collar 963 4DT FS SV4BF 4DFSP Fire stop 9...

Страница 22: ...Figure 29 Vent Pipe Clearances Initial Installation QUALIFIED INSTALLERS ONLY When planning an installation it is necessary to select the proper length of vent pipe for the particular requirements Th...

Страница 23: ...er vertical vent lengths necessitate greater restriction position 1 is open and position 5 is maximum restriction Figure 31 NOTE The total length of the vent pipes can not exceed 32 feet 15 12 m Any c...

Страница 24: ...ive heat from possibly melting the vinyl siding 5 Horizontal pipes must be supported every 3 feet 914 mm Plumber s all round strap will suffice 6 When running horizontal pipe clearances to combustible...

Страница 25: ...nd from the vent cap assembly to the outer wall of the vent pipe Bend any remaining portion of the strap back towards the vent cap Security Secure Vent uses a twist lock cap Step 5 Position the horizo...

Страница 26: ...shing to the roof with roofing nails Use a non hardening sealant between the uphill edge of the flashing and the roof Insure the roofing material overlaps the top edge of the flashing Verify that you...

Страница 27: ...sions in the same manner as shown in Figure 30 plumber s tape connected to wall strap Wall strap 45 elbows x2 Nails Ceiling firestop Ceiling Second floor Use clearances to as defined by appliance and...

Страница 28: ...urrently installed or if you plan to install the Optional Fan Kit 50 1211 in the future See Figure 1 for possible electrical wire access locations Refer to local electrical bylaw codes for proper inst...

Страница 29: ...e pressure exceeds 1 2 PSIG 3 45 KPa or damage will occur to the valve The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressu...

Страница 30: ...omatically turn off a few minutes after the appliance is shut off The fireplace must be electrically connected and grounded in accordance with local codes or in the absence of local codes with the cur...

Страница 31: ...ETREAT 1 Use a flat head screwdriver or a 1 4 socket to remove the six 6 screws securing the back cover see Figure 46 Figure 46 Removing Back Plate From Retreat Figure 43 Installing Temperature Sensor...

Страница 32: ...rner comes with six 6 locator pins pointed out in Figure 49 which make alignment easier The locator pins are long enough to go through the charcoal and be used to locate the logs Carefully set the thr...

Страница 33: ...and wait for it to cool down Then remove the glass and rearrange the ember material ensuring none of the burner ports are densely blocked Maintenance Once a year the charcoal pieces and logs should b...

Страница 34: ...the liner is in the firebox adjust it so it is flush with the front of the firebox and so that there is some clearance behind the pilot INSTALLATION OF THE FASCIA 1 Ensure the lip with the tabs on th...

Страница 35: ...ith thermopile circuit Check gas line pressure Check for flame impingement on thermopile If low see Pilot will not remain lit Check thermopile for minimum of 300 mV when burner is switched on Check wi...

Страница 36: ...6 6 Fan Controller 115V EC 039 7 Convection Blower 115V EG22 001 7 Convection Blower Kit 115V 50 1211 8 Enviro Logo Gel Decal 50 322 Blank Orifice 73 50 343 9 On Off Remote Control Kit 50 559 Programm...

Страница 37: ...Bottom Door Black Enameled 50 1226 22 Chalet Face Inset Bottom Door Bronze Enameled 50 1315 23 Chalet Inset Brushed Nickel 50 1309 23 Chalet Inset Brushed Gold 50 1310 23 Chalet Inset Bronze Enameled...

Страница 38: ...Parts Diagram Components Retreat Fireplace 20 10 19 6 7 18 3 4 17 5 9 16 2 8 15 14 13 12 1 11 21 The Retreat Components July 2005 38...

Страница 39: ...39 Parts Diagram Fascia The Retreat Fascia July 2005 23 22 25 24...

Страница 40: ...nst manufacturing defects on all the electrical components and gas components paint is also covered against flaking This offer includes parts and labour for one year and parts only thereafter Your dea...

Страница 41: ...______________________________ MODEL ___________________________________ SERIAL NUMBER ___________________________ DATE OF PURCHASE _____________ dd mm yyyy DATE OF INSTALLATION ___________ dd mm yyyy...

Отзывы: