Safety Warnings & Recommendations

ELECTRICAL: The use of a surge protected power bar is recommended. 

The unit must be grounded. 

The grounded electrical cord should be connected to a standard 110-120 volts (4.2 Amps), 60 hertz electrical 

outlet and also must be accessible. If this power cord should become damaged, a replacement power cord 

must be purchased from the manufacturer or a qualified Enviro dealer. Be careful that the electrical cord is 

not trapped under the appliance and that it is clear of any hot surfaces or sharp edges. This unit’s maximum 

power requirement is 504 watts.  

GLASS:

 Do not abuse the glass by striking or slamming the door.  Do not attempt to operate the stove with 

broken glass. The stove uses ceramic glass. Replacement glass must be purchased from an Enviro dealer.  

Do not attempt to open the door and clean the glass while the unit is in operation or if glass is hot. To clean 

the glass, use a soft cotton cloth and mild window cleaner, gas or wood stove glass cleaner, or take a damp 

paper towel and dip into the fly ash. This is a very mild abrasive and will not damage the glass.

KEEP ASH PAN FREE OF RAW FUEL. 

DO NOT PLACE UNBURNED OR NEW PELLET FUEL IN ASH PAN. 

A fire in the ash pan may occur.

INSTALLATION:

  Contact your local building or fire official to obtain a permit and any information on 

installation restrictions and inspection requirements for your area. 
Be sure to maintain the structural integrity of your home when passing a vent through walls, ceilings, or 

roofs, and all construction meets local building codes. It is recommended that the unit be secured into its 

position in order to avoid any displacement. This appliance must be installed on a floor with an adequate 

load  bearing  capacity,  if  existing  construction  doesn’t  meet  load  capacity,  suitable  measures  (e.g.  load 

distributing plate) must be taken to achieve it.
DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT.

DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.

FRESH AIR:

 This unit uses large quantities of air for combustion; outside Fresh Air connection is 

strongly 

recommended. Fresh Air 

must

 be connected to all units installed in Mobile and “Air Tight Homes” (R2000) 

or where required by local codes. 
Consider all large air moving devices when installing your unit and provide room air accordingly. NOTE: 

Extractor fans when operating in the same room or space as the appliance may cause problems. Limited air 

for combustion may result in poor performance, smoking and other side effects of poor combustion. 
The  stove’s  exhaust  system  works  with  negative  combustion  chamber  pressure  and  a  slightly  positive 

chimney pressure. It is very important to ensure that the exhaust system be sealed and airtight. The ash 

pan and viewing door must be locked securely for proper and safe operation of the pellet stove.
Do not burn with insufficient combustion air. A periodic check is recommended to ensure proper combustion 

air is admitted to the combustion chamber.  Setting the proper combustion air is achieved by adjusting the 

slider damper located on the left side of the stove.
Soot or creosote may accumulate when the stove is operated under incorrect conditions such as an rich 

burn (black tipped, lazy orange flames).
If you have any questions with regards to your stove or the above-mentioned information, please feel free 

to contact your local dealer for further clarification and comments.

SINCE SHERWOOD INDUSTRIES LTD. HAS NO CONTROL OVER THE INSTALLATION OF YOUR 

STOVE, SHERWOOD INDUSTRIES LTD. GRANTS NO WARRANTY IMPLIED OR STATED FOR THE 

INSTALLATION  OR  MAINTENANCE  OF  YOUR  STOVE.  THEREFORE,  SHERWOOD  INDUSTRIES 

LTD. ASSUMES NO RESPONSIBILITY FOR ANY CONSEqUENTIAL DAMAGE(S).

SAVE THIS INSTRUCTION MANUAL FOR FUTURE REFERENCE.

Содержание M55C-FPI

Страница 1: ...TY DAMAGE BODILY INJURY OR EVEN DEATH Contact your building or fire officials about restrictions and installation inspection requirements in your area SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONS...

Страница 2: ...Outside Fresh Air Connection 11 Exhaust And Fresh Air Intake Locations 11 Masonry Fireplace Installation 12 Positive Flue Connection 13 Built In Installation 14 Horizontal Exhaust Through Wall Instal...

Страница 3: ...ot operate the stove again until you are certain the chimney and its lining have not been damaged OPERATION The door and ash drawer must be kept closed when the unit is in operation to prevent fume sp...

Страница 4: ...ity suitable measures e g load distributing plate must be taken to achieve it DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING...

Страница 5: ...HEAT LEVEL and Fans will drop down to the LOW setting until the thermostat contacts close again AUTO OFF MODE Requires a thermostat When the thermostat contacts close the unit will light automatically...

Страница 6: ...l Pellet Heater 6mm dia Pellets wood corn wheat barley Voltage Current Max Power 110 120 V 4 2 Amps 504 Watts Frequency Hopper Capacity Consumption on Low 60 Hz up to 50 lb 22 7 Kg 1 5 lb hr 0 68 Kg h...

Страница 7: ...ed Fresh Air must be connected to all units installed in Mobile and Air Tight Homes R2000 or where required by local codes 7 Do not obtain combustion air from an attic garage or any unventilated space...

Страница 8: ...the length of the bolts masonry bricks may be placed under the frame 4 Once level position the Insert Frame in the fireplace cavity so that the Surround Panel is flush with the front of the fireplace...

Страница 9: ...Req thermostat co close again automatically will drop down will return to p and it will rest To Turn Off S AUTO OFF Pour d marre qualit de su carburants A pot de br lure Pour faire fon MODE HIGH tre a...

Страница 10: ...ermination locations Table 2 Use in conjunction with Figure 6 for allowable exterior vent termination locations Letter Minimum Clearance Description A 24 in 61 cm Above grass top of plants wood or any...

Страница 11: ...n connecting to an outside fresh air source do not use plastic or combustible pipe A 3 minimum 76 mm ID inside diameter steel aluminum or copper pipe or ducting should be used The inlet must have a sc...

Страница 12: ...ry Chimneys 6 It is necessary to permanently seal any opening between the masonry of the fireplace and the facing masonry Figure 9 Masonry fireplace installation When installing the insert into a maso...

Страница 13: ...ir from the fireplace from entering the chimney which will affect proper Figure 10 Masonry fireplace positive flue installation drafting of appliance A qualified installer should evaluate the existing...

Страница 14: ...ble cement board and a layer of tile The air space must be supported with sheet metal studs and have no combustible material in the air space All venting for Built In installation must use PL or L ven...

Страница 15: ...st caused by airflow around the structure Follow vent manufacturer guidelines for installation clearance to combustibles and sealing of venting High temp Sealant must be used when connecting vent pipe...

Страница 16: ...nation Installation Figure 12 Venting horizontally with rise NOTE This venting configuration is only for use with the Built In installation Wall framing Wall thimble Termination cap Vertical section o...

Страница 17: ...PL vent upward from the tee Make sure that you install support brackets to keep the vent straight and secure All joints in the exhaust venting system must be fastened with at least three 3 screws 3 I...

Страница 18: ...in the exhaust venting system must be fastened with at least three 3 screws 3 Install ceiling thimble and secure the flashing as you go through the roof 4 Ensure that the rain cap is approximately 24...

Страница 19: ...long periods of burning the fire builds up or there is a build up of clinkers this would be a sign that the fuel quality is poor this requires more air The easiest way to make sure that an efficient...

Страница 20: ...If the 3 light is flashing unit may be out of fuel Check the Door and Ash Pan door THEY MUST BE CLOSED TIGHT See section 8 The Fuel will not light Check the fuse on the circuit board If the unit still...

Страница 21: ...may require vertical section to move termination into a low pressure zone To reset Circuit Board after a trouble code push the ON OFF button 5 Unit is on but auger motor does not turn at all Check the...

Страница 22: ...of the Heat Level button make sure the thermostat is calling for heat Call your local dealer for service 10 The stove keeps going out If the stove goes out and leaves fresh unburned fuel in the burn p...

Страница 23: ...Motor Grey Grey Orange Orange White Grey Grey White Blue Yellow Auger Motor White Yellow Vacuum Switch Connect Thermostat Here Brown Brown Blue Purple Yellow Red Thermostat Combustion Blower Black Bla...

Страница 24: ...uger Collar with Screw 50 968 14 Auger Motor 2rpm 50 2054 15 Exhaust Motor Capacitor including Strap 50 2053 16 Agitator Drive Shaft with Sprocket 50 1698 17 Motor Drive Sprocket 50 1700 18 Auger Moto...

Страница 25: ...Set of 2 50 2294 54 Bearings with Mounting Bolts Set of 4 50 2295 55 M55C FPI Milan Empress FPI 2 Amp Small Fuse 50 2302 56 M55C FPI Milan Empress FPI 4 Amp Small Fuse Ignitor 50 2303 57 Agitator Driv...

Страница 26: ...2276 68 M55C FPI Cast Ash Door Chestnut 50 2282 68 M55C FPI Cast Ash Door DB 50 2299 69 M55C FPI Cast Surround Trim Only PD 50 2272 69 M55C FPI Cast Surround Trim Only Beach 50 2278 69 M55C FPI Cast...

Страница 27: ...27 Parts Diagram Components 6 48 1 2 3 4 8 23 14 10 11 15 9 29 21 7 42 24 12 54 25 17 16 18 40 5 22 45 41 49 47 52 53 13 19 20 37...

Страница 28: ...Parts Diagram Steel 69 70 38 28 57 26 27 63 5 62 61 36 51 59 66 67 68 64 65 30 37 39 44 28...

Страница 29: ...ain restrictions and exclusions apply to this warranty Limited Two 2 Year Warranty Under this warranty Sherwood Industries Ltd covers Ignitor Auger Motor Circuit Board Timers Temp Sensors Blowers Vacu...

Страница 30: ...ify the Limited Warranty on this stove If unsure as to the extent of this Limited Warranty contact your authorized Enviro dealer before installation 10 Sherwood Industries Ltd will not be responsible...

Страница 31: ...vered per our warranty service fee reimbursement schedule Labour rates are set per component and as such total labour costs may not be covered 27 Sherwood Industries Ltd is not liable for freight or l...

Страница 32: ...AL NUMBER ___________________________ DATE OF PURCHASE _____________ dd mm yyyy DATE OF INSTALLATION ___________ dd mm yyyy MAGNEHELIC AT INSTALL ___________________ INSTALLER S SIGNATURE ____________...

Отзывы: