background image

Installation

c

learanceS

 

to

 c

ombuStibleS

:

Figure 4: M55C-FPI Clearance to Combustibles. 

t

hermoStat

 i

nStallation

:

1. Install the wall thermostat (millivolt rated thermostat 

recommended, or a 12/24 Volt rated thermostat set to 

millivolts) in a location that is not too close to the unit 

but will effectively heat the desired area.

2.  Connect  the  Thermostat  or  Timer  to  the  thermostat 

wires on the unit. (Fig. 5)

If the heat in the room becomes too great, the high limit 

switch may turn the stove off and the switch will have to 

be manually reset. To reset the high limit switch:
-open the hopper lid
-remove plug under control panel
-use screwdriver to press down on the button on top of 

the snap disk switch

Figure 5: Thermostat connection wires.

9

Certified for use in Canada & USA

Certifié pour installation au 

Canada et aux Etats-Unis.

Model / Modèle: M55C-FPI

Listed Room Heater, Pelletized Fuel Type (Appareil de chauffage à granules  certifié)

Input rating when using: Wood Pellets/Corn - 55,000BTU (16.1KW*hr)  Wheat/Barley - 53,000BTU (15.5KW*hr)

(Le chauffage d'énergie avec: Boulettes de bois/lMaïs - 55,000BTU (16.1KW*hr) Blé/l'Orge - 53,000BTU (15.5KW*hr)) 

Tested to (Testée selon): ASTM 1509-04.  US Environmental Protection Agency, certified to comply July 1, 1990, particulate 

emission standards. (États-Unis Environnemental Protection Agence, a certifié pour conformer au Juillet 1, 1990, les normes de 

particules d'émission.) 

Standard for Fireplace Inserts / Norme pour des Insertions de Cheminée: ULC S628

Install and use only in accordance with the manufacturer's installation and operating instructions. Contact local building 

or fire officials about restrictions and installation inspection in your area.  Do not connect this unit to a chimney flue 

serving  another  appliance.  Inspect  and  clean  exhaust  venting  system  frequently.  See  local  building  code  and 

manufacturer's  instructions  for  precautions  required  for  passing  a  chimney  through  a  combustible  wall  or  ceiling.  

ELECTRICAL RATING: 120 Volts, 60Hz, 4.2 Amps.  Route Cord Away From Heater.

For use with pelletized solid fuels - wood, corn, wheat, & barley only. Operate only with viewing door and ash removal 

door closed. Only replace glass with ceramic glass. Components required for installation:  listed 4inch (100 mm) 

stainless steel chimney liner.  

Installez et utilisez cet appareil seulement selon les instructions d'installation et d'opération du fabricant. Contactez les 

autorités locales de votre quartier concernant les restrictions et les inspections d'installation. Inspectez et nettoyez le 

système d'échappement fréquemment. Consultez les codes de bâtiment locaux et les instructions du fabricant pour les 

précautions  à  prendre  lorsque  une  cheminée  doit  être  installée  au  travers  un  mur  ou  un  plafond  combustible. 

CLASSEMENT ÉLECTRIQUE : 120 Volts, 60 Hz, 4.2 Amps. Placez le câble électrique loin de la chaleur. 

MANUFACTURED BY / FABRIQUE PAR:

SHERWOOD INDUSTRIES LTD.

VICTORIA BC CANADA

DATE OF MANUFACTURE / DATE DE FABRICATION:

J     F      M     A    M    J     J     A     S     O     N     D          2010     2011     2012

CAUTION:

HOT WHILE IN OPERATION. DO 

NOT TOUCH. KEEP CHILDREN, 

CLOTHING AND FURNITURE 

AWAY.  CONTACT MAY CAUSE 

BURNS. SEE NAMEPLATE AND 

INSTRUCTIONS.

 

ATTENTION:

L'APPAREIL EST CHAUD LORSQU'IL                                                             

FONCTIONNE. NE PAS TOUCHER. GARDER LES ENFANTS, 

LES VÊTEMENTS ET LES MEUBLES ÉLOIGNÉS DE 

L'APPAREIL EN MARCHE. UN CONTACT AVEC CELUI-CI 

POURRAIT RÉSULTER EN DES BRÛLURES. VEUILLEZ 

VOIR LA PLAQUE DU FABRICANT ET LES INSTRUCTIONS.

DO NOT REMOVE THIS LABEL / NE RETIREZ PAS CETTE ÉTIQUETTE

C-12224

WH-M55C-FPI

Serial No. / No. De Serié:

To Start Stove: Select fuel type mode; PREMIUM PELLETS for superior quality pellet fuel, REGULAR PELLETS for all 

grades of wood pellets & MULTIFUEL for all other fuels. Press the ON / OFF button. For first time use, a small handful 

of pellets in the burn pot liner will speed up ignition.

To Operate Stove: MANUAL MODE: When a fire has been established the stove settings are adjustable. / HIGH/LOW 

MODE:  (Requires  a  thermostat)  When  the  thermostat  calls  for  heat  the  stove  settings  are  adjustable.    When  the 

thermostat contacts open, the HEAT LEVEL and Fans will drop down to the LOW setting until the thermostat contacts 

close  again.  / AUTO/OFF  MODE:  (Requires  a  thermostat)  When  the  thermostat  contacts  close,  the  unit  will  light 

automatically. Once up to temperature the stove settings are adjustable. When the thermostat contacts open, the stove 

will drop down to the LOW settings for 30 minutes. If within the 30 min the thermostat contacts close, the HEAT LEVEL 

will return to previous MANUAL setting or if the thermostat contacts remain open the stove begin its shutdown routine 

and it will restart when the thermostat closes.

To Turn Off Stove: MANUAL and HI / LOW mode: Press the ON / OFF button

AUTO / OFF mode: Turn the thermostat down or off.

Pour démarrer le poêle: Choisir le mode pour le carburant ; PREMIUM PELLETS pour le carburant de boulette de 

qualité  de  superior,  REGULAR  PELLET  pour  tous  degrés  de  boulettes  de  bois  &  MULTIFUEL  pour  tous  autres 

carburants. Appuyer sur le bouton "ON/OFF". Pour l’usage de première fois, une petite poignée de boulettes dans le 

pot de brûlure hâtera l'allumage. 

Pour faire fonctionner le poêle :  MODE MANUEL : Lorsque le feu est bien établi, les réglages peuvent être ajustés. / 

MODE "HIGH/LOW" : (Nécessite un thermostat) Lorsque le  thermostat requière de la chaleur, les réglages peuvent 

être  ajustés.  Lorsque  les  contacts  du  thermostat  ouvrent,  le  réglage  du  niveau  de  chaleur  et  les  ventilateurs 

s'ajusteront  au  réglage  "  bas  "  jusqu'à  ce  que  les  contacts  du  thermostat  se  referment.  /  MODE  "AUTO/OFF"  : 

(Nécessite un thermostat) Lorsque les contacts du thermostat ferment, le poêle s'allumera automatiquement. Lorsque 

la température adéquate est atteinte, les réglages peuvent être ajustés. Lorsque les contacts du thermostat ouvrent, le 

poêle s'ajustera aux réglages "LOW" pendant 30 minutes. Si les contacts du thermostat sont fermés pendant ces 30 

minutes, le réglage de niveau de chaleur retournera en réglages "MANUEL" ou si les contacts du thermostat restent 

ouverts, le poêle entamera le processus d'arrêt et il vouloir redémarrer lorsque les contacts du thermostat refermer. 

Pour éteindre le poêle : MODE MANUEL ET " HIGH/LOW " : Appuyer sur le bouton "ON/OFF". 

MODE "AUTO / OFF" : Régler le thermostat à la baisse ou éteignez le.

Utilisation avec granules  - le bois, le maïs, le blé, & l'orge seulement. Utiliser seulement lorsque les 

portes avants et la porte du réceptacle de cendre sont fermées. Si une ou des vitres devaient être 

remplacées, utilisez seulement du verre céramique. Les composantes requises pour l'installation: 

une rêvetement de cheminée reprisé en acier inoxydable 4”.

16622

A  Sidewall to center of unit (De la paroi au centre de l'unité) 

24” (610 mm)

B  Sidewall to surround panel (De la paroi à l'entoure le panneau) 

2” (51 mm)

C  Bottom of unit to an unshielded 12” (305 mm) mantle 
 

(Le fond de l'unité à un manteau de cheminée non blindé) 

33“ (838 mm)

D  Unit to top facing (protruding ¾” [19 mm]) 
 

(De l'unité au sommet du parement) 

0” (0 mm)

E  Unit to side facing (protruding ¾” [19 mm]) (De l'unité au côté du parement) 

0” (0 mm)

F  From door opening of unit to edge of floor protection 
 

(De la porte ouvrant au devant de protection de plancher) 

6” (152 mm)

G  From side of unit to edge of floor protection 
 

(De l'ouverture de porte pour prendre parti de protection de plancher) 

6” (152 mm)

C

A

E

B

D

Adjacent 

 w

al

l

G

F

Combustible floors must be protected 

by a non-combustible material. 

- See Owners Manual. 

Le plancher combustible doit être 

protégé par un matériel incombustible. 

- Consultez le manual.

INSTALLED AS A FIREPLACE INSERT STOVE MODEL (FPI) / A INSTALLE 

COMME UN MODELE SUR PIED DE POELE.

Minimum clearances to combustible materials./ Les dégagements minimums aux 

matériels combustibles:



These dimensions are minimum clearances.

It  is  recommended  that  you  ensure 

sufficient  room  for  servicing,  routine 

cleaning and maintenance.

The unit must be installed with a minimum 

of 6” (152 mm) of floor  protection in front 

of and to the sides of the door opening.

Содержание M55C-FPI

Страница 1: ...TY DAMAGE BODILY INJURY OR EVEN DEATH Contact your building or fire officials about restrictions and installation inspection requirements in your area SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONS...

Страница 2: ...Outside Fresh Air Connection 11 Exhaust And Fresh Air Intake Locations 11 Masonry Fireplace Installation 12 Positive Flue Connection 13 Built In Installation 14 Horizontal Exhaust Through Wall Instal...

Страница 3: ...ot operate the stove again until you are certain the chimney and its lining have not been damaged OPERATION The door and ash drawer must be kept closed when the unit is in operation to prevent fume sp...

Страница 4: ...ity suitable measures e g load distributing plate must be taken to achieve it DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING...

Страница 5: ...HEAT LEVEL and Fans will drop down to the LOW setting until the thermostat contacts close again AUTO OFF MODE Requires a thermostat When the thermostat contacts close the unit will light automatically...

Страница 6: ...l Pellet Heater 6mm dia Pellets wood corn wheat barley Voltage Current Max Power 110 120 V 4 2 Amps 504 Watts Frequency Hopper Capacity Consumption on Low 60 Hz up to 50 lb 22 7 Kg 1 5 lb hr 0 68 Kg h...

Страница 7: ...ed Fresh Air must be connected to all units installed in Mobile and Air Tight Homes R2000 or where required by local codes 7 Do not obtain combustion air from an attic garage or any unventilated space...

Страница 8: ...the length of the bolts masonry bricks may be placed under the frame 4 Once level position the Insert Frame in the fireplace cavity so that the Surround Panel is flush with the front of the fireplace...

Страница 9: ...Req thermostat co close again automatically will drop down will return to p and it will rest To Turn Off S AUTO OFF Pour d marre qualit de su carburants A pot de br lure Pour faire fon MODE HIGH tre a...

Страница 10: ...ermination locations Table 2 Use in conjunction with Figure 6 for allowable exterior vent termination locations Letter Minimum Clearance Description A 24 in 61 cm Above grass top of plants wood or any...

Страница 11: ...n connecting to an outside fresh air source do not use plastic or combustible pipe A 3 minimum 76 mm ID inside diameter steel aluminum or copper pipe or ducting should be used The inlet must have a sc...

Страница 12: ...ry Chimneys 6 It is necessary to permanently seal any opening between the masonry of the fireplace and the facing masonry Figure 9 Masonry fireplace installation When installing the insert into a maso...

Страница 13: ...ir from the fireplace from entering the chimney which will affect proper Figure 10 Masonry fireplace positive flue installation drafting of appliance A qualified installer should evaluate the existing...

Страница 14: ...ble cement board and a layer of tile The air space must be supported with sheet metal studs and have no combustible material in the air space All venting for Built In installation must use PL or L ven...

Страница 15: ...st caused by airflow around the structure Follow vent manufacturer guidelines for installation clearance to combustibles and sealing of venting High temp Sealant must be used when connecting vent pipe...

Страница 16: ...nation Installation Figure 12 Venting horizontally with rise NOTE This venting configuration is only for use with the Built In installation Wall framing Wall thimble Termination cap Vertical section o...

Страница 17: ...PL vent upward from the tee Make sure that you install support brackets to keep the vent straight and secure All joints in the exhaust venting system must be fastened with at least three 3 screws 3 I...

Страница 18: ...in the exhaust venting system must be fastened with at least three 3 screws 3 Install ceiling thimble and secure the flashing as you go through the roof 4 Ensure that the rain cap is approximately 24...

Страница 19: ...long periods of burning the fire builds up or there is a build up of clinkers this would be a sign that the fuel quality is poor this requires more air The easiest way to make sure that an efficient...

Страница 20: ...If the 3 light is flashing unit may be out of fuel Check the Door and Ash Pan door THEY MUST BE CLOSED TIGHT See section 8 The Fuel will not light Check the fuse on the circuit board If the unit still...

Страница 21: ...may require vertical section to move termination into a low pressure zone To reset Circuit Board after a trouble code push the ON OFF button 5 Unit is on but auger motor does not turn at all Check the...

Страница 22: ...of the Heat Level button make sure the thermostat is calling for heat Call your local dealer for service 10 The stove keeps going out If the stove goes out and leaves fresh unburned fuel in the burn p...

Страница 23: ...Motor Grey Grey Orange Orange White Grey Grey White Blue Yellow Auger Motor White Yellow Vacuum Switch Connect Thermostat Here Brown Brown Blue Purple Yellow Red Thermostat Combustion Blower Black Bla...

Страница 24: ...uger Collar with Screw 50 968 14 Auger Motor 2rpm 50 2054 15 Exhaust Motor Capacitor including Strap 50 2053 16 Agitator Drive Shaft with Sprocket 50 1698 17 Motor Drive Sprocket 50 1700 18 Auger Moto...

Страница 25: ...Set of 2 50 2294 54 Bearings with Mounting Bolts Set of 4 50 2295 55 M55C FPI Milan Empress FPI 2 Amp Small Fuse 50 2302 56 M55C FPI Milan Empress FPI 4 Amp Small Fuse Ignitor 50 2303 57 Agitator Driv...

Страница 26: ...2276 68 M55C FPI Cast Ash Door Chestnut 50 2282 68 M55C FPI Cast Ash Door DB 50 2299 69 M55C FPI Cast Surround Trim Only PD 50 2272 69 M55C FPI Cast Surround Trim Only Beach 50 2278 69 M55C FPI Cast...

Страница 27: ...27 Parts Diagram Components 6 48 1 2 3 4 8 23 14 10 11 15 9 29 21 7 42 24 12 54 25 17 16 18 40 5 22 45 41 49 47 52 53 13 19 20 37...

Страница 28: ...Parts Diagram Steel 69 70 38 28 57 26 27 63 5 62 61 36 51 59 66 67 68 64 65 30 37 39 44 28...

Страница 29: ...ain restrictions and exclusions apply to this warranty Limited Two 2 Year Warranty Under this warranty Sherwood Industries Ltd covers Ignitor Auger Motor Circuit Board Timers Temp Sensors Blowers Vacu...

Страница 30: ...ify the Limited Warranty on this stove If unsure as to the extent of this Limited Warranty contact your authorized Enviro dealer before installation 10 Sherwood Industries Ltd will not be responsible...

Страница 31: ...vered per our warranty service fee reimbursement schedule Labour rates are set per component and as such total labour costs may not be covered 27 Sherwood Industries Ltd is not liable for freight or l...

Страница 32: ...AL NUMBER ___________________________ DATE OF PURCHASE _____________ dd mm yyyy DATE OF INSTALLATION ___________ dd mm yyyy MAGNEHELIC AT INSTALL ___________________ INSTALLER S SIGNATURE ____________...

Отзывы: