Safety Warnings & Recommendations

This manual is designed for the technician in conjunction with the owner’s manual. *

Please read this entire Technical Manual before installing or operating your Enviro Pellet Stove. 

Failure to follow these instructions may result in property damage, bodily injury or even death. 

Any unauthorized modification of the appliance or use of replacement parts not recommended 

by the manufacturer is prohibited. All national and local regulations shall be complied with 

when operating this appliance.

Caution: Do not connect to any air distribution duct or system.

Warning:

 Never place wood, paper, furniture, drapes or other combustible materials within 48” (122cm) 

of the front of the unit, 12” (30.5cm) from each side, and 3” (7.6cm) from the back of the unit. Do not let 

children or pets touch it when it is hot. 
To  prevent  the  possibility  of  a  fire,  ensure  that  the  appliance  is  properly  installed  by  adhering  to  the 

installation instructions. An Enviro dealer will be happy to assist you in obtaining information with regards 

to your local building codes and installation restrictions.

FIRE EXTINGUISHER AND SMOKE DETECTION: 

All homes with a pellet burning stove should have at 

least one fire extinguisher in a central location known to all in the household. Smoke detectors should be 

installed and maintained in the room containing the stove. If it sounds the alarm, correct the cause but do 

not deactivate. You may choose to relocate the smoke detection devise within the room; DO NOT REMOVE 

THE SMOKE DETECTOR FROM THE ROOM.

CHIMNEY OR RUN AWAY FIRE: 

Call local fire department (or dial 911). Close the draft fully. Extinguish 

the fire in the burn pot liner with a cup of water and close the door. Examine the flue pipes, chimney, attic, 

and roof of the house, to see if any part has become hot enough to catch fire. If necessary, spray with fire 

extinguisher or water from the garden hose. IMPORTANT:

 

Do not operate the stove again until you are 

certain the chimney and its lining have not been damaged.

OPERATION:

 The door and ash drawer must be kept closed when the unit is in operation to prevent 

fume spillage and for proper and safe operation of the pellet stove. Also ensure all gaskets on the door 

are checked and replaced when necessary. 

Unit hot while in operation. Keep children, clothing and 

furniture away. Contact may cause skin burns.
CAUTION: 

When operating during adverse weather, if the unit exhibits dramatic changes in combustion 

stop using the unit immediately. 

FUEL

:  This stove is designed and approved to only burn wood pellets of any quality, corn, wheat, and 

barley.  Dirty fuel will adversely affect the operation and performance of the unit and may void the warranty. 

Check  with  your  dealer  for  fuel  recommendations. 

THE  USE  OF  CORD  WOOD  IS  PROHIBITED  BY 

LAW. Do not burn garbage or flammable fluids such as gasoline, naphtha or engine oil.
SOOT:

 Operation of the stove with insufficient combustion air will result in the formation of soot which will 

collect on the glass, the heat exchanger, the exhaust vent system, and may stain the outside of the house.  

Frequently check your stove and adjust the slider/damper as needed to ensure proper combustion. 

See: 

S

lider

/d

amper

 S

etting

”.

CLEANING:

 There will be some build up of fly ash and small amounts of creosote in the exhaust. This will 

vary due to the ash content of the fuel used and the operation of the stove. It is advisable to inspect and 

clean the exhaust vent semi-annually or every two tons of pellets.
The appliance, flue gas connector and the chimney flue require regular cleaning. Check them for blockage 

prior to re-lighting after a prolonged shut down period.

ASHES:

 Disposed ashes should be placed in a metal container with a tight fitting lid. The closed container 

of ashes should be on a non-combustible surface, well away from all combustible materials pending final 

disposal. If the ashes are disposed of by burial in soil or otherwise locally dispensed, they should be retained 

in the closed container until all cinders have thoroughly cooled.

Содержание M55C-FPI

Страница 1: ...TY DAMAGE BODILY INJURY OR EVEN DEATH Contact your building or fire officials about restrictions and installation inspection requirements in your area SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONS...

Страница 2: ...Outside Fresh Air Connection 11 Exhaust And Fresh Air Intake Locations 11 Masonry Fireplace Installation 12 Positive Flue Connection 13 Built In Installation 14 Horizontal Exhaust Through Wall Instal...

Страница 3: ...ot operate the stove again until you are certain the chimney and its lining have not been damaged OPERATION The door and ash drawer must be kept closed when the unit is in operation to prevent fume sp...

Страница 4: ...ity suitable measures e g load distributing plate must be taken to achieve it DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING...

Страница 5: ...HEAT LEVEL and Fans will drop down to the LOW setting until the thermostat contacts close again AUTO OFF MODE Requires a thermostat When the thermostat contacts close the unit will light automatically...

Страница 6: ...l Pellet Heater 6mm dia Pellets wood corn wheat barley Voltage Current Max Power 110 120 V 4 2 Amps 504 Watts Frequency Hopper Capacity Consumption on Low 60 Hz up to 50 lb 22 7 Kg 1 5 lb hr 0 68 Kg h...

Страница 7: ...ed Fresh Air must be connected to all units installed in Mobile and Air Tight Homes R2000 or where required by local codes 7 Do not obtain combustion air from an attic garage or any unventilated space...

Страница 8: ...the length of the bolts masonry bricks may be placed under the frame 4 Once level position the Insert Frame in the fireplace cavity so that the Surround Panel is flush with the front of the fireplace...

Страница 9: ...Req thermostat co close again automatically will drop down will return to p and it will rest To Turn Off S AUTO OFF Pour d marre qualit de su carburants A pot de br lure Pour faire fon MODE HIGH tre a...

Страница 10: ...ermination locations Table 2 Use in conjunction with Figure 6 for allowable exterior vent termination locations Letter Minimum Clearance Description A 24 in 61 cm Above grass top of plants wood or any...

Страница 11: ...n connecting to an outside fresh air source do not use plastic or combustible pipe A 3 minimum 76 mm ID inside diameter steel aluminum or copper pipe or ducting should be used The inlet must have a sc...

Страница 12: ...ry Chimneys 6 It is necessary to permanently seal any opening between the masonry of the fireplace and the facing masonry Figure 9 Masonry fireplace installation When installing the insert into a maso...

Страница 13: ...ir from the fireplace from entering the chimney which will affect proper Figure 10 Masonry fireplace positive flue installation drafting of appliance A qualified installer should evaluate the existing...

Страница 14: ...ble cement board and a layer of tile The air space must be supported with sheet metal studs and have no combustible material in the air space All venting for Built In installation must use PL or L ven...

Страница 15: ...st caused by airflow around the structure Follow vent manufacturer guidelines for installation clearance to combustibles and sealing of venting High temp Sealant must be used when connecting vent pipe...

Страница 16: ...nation Installation Figure 12 Venting horizontally with rise NOTE This venting configuration is only for use with the Built In installation Wall framing Wall thimble Termination cap Vertical section o...

Страница 17: ...PL vent upward from the tee Make sure that you install support brackets to keep the vent straight and secure All joints in the exhaust venting system must be fastened with at least three 3 screws 3 I...

Страница 18: ...in the exhaust venting system must be fastened with at least three 3 screws 3 Install ceiling thimble and secure the flashing as you go through the roof 4 Ensure that the rain cap is approximately 24...

Страница 19: ...long periods of burning the fire builds up or there is a build up of clinkers this would be a sign that the fuel quality is poor this requires more air The easiest way to make sure that an efficient...

Страница 20: ...If the 3 light is flashing unit may be out of fuel Check the Door and Ash Pan door THEY MUST BE CLOSED TIGHT See section 8 The Fuel will not light Check the fuse on the circuit board If the unit still...

Страница 21: ...may require vertical section to move termination into a low pressure zone To reset Circuit Board after a trouble code push the ON OFF button 5 Unit is on but auger motor does not turn at all Check the...

Страница 22: ...of the Heat Level button make sure the thermostat is calling for heat Call your local dealer for service 10 The stove keeps going out If the stove goes out and leaves fresh unburned fuel in the burn p...

Страница 23: ...Motor Grey Grey Orange Orange White Grey Grey White Blue Yellow Auger Motor White Yellow Vacuum Switch Connect Thermostat Here Brown Brown Blue Purple Yellow Red Thermostat Combustion Blower Black Bla...

Страница 24: ...uger Collar with Screw 50 968 14 Auger Motor 2rpm 50 2054 15 Exhaust Motor Capacitor including Strap 50 2053 16 Agitator Drive Shaft with Sprocket 50 1698 17 Motor Drive Sprocket 50 1700 18 Auger Moto...

Страница 25: ...Set of 2 50 2294 54 Bearings with Mounting Bolts Set of 4 50 2295 55 M55C FPI Milan Empress FPI 2 Amp Small Fuse 50 2302 56 M55C FPI Milan Empress FPI 4 Amp Small Fuse Ignitor 50 2303 57 Agitator Driv...

Страница 26: ...2276 68 M55C FPI Cast Ash Door Chestnut 50 2282 68 M55C FPI Cast Ash Door DB 50 2299 69 M55C FPI Cast Surround Trim Only PD 50 2272 69 M55C FPI Cast Surround Trim Only Beach 50 2278 69 M55C FPI Cast...

Страница 27: ...27 Parts Diagram Components 6 48 1 2 3 4 8 23 14 10 11 15 9 29 21 7 42 24 12 54 25 17 16 18 40 5 22 45 41 49 47 52 53 13 19 20 37...

Страница 28: ...Parts Diagram Steel 69 70 38 28 57 26 27 63 5 62 61 36 51 59 66 67 68 64 65 30 37 39 44 28...

Страница 29: ...ain restrictions and exclusions apply to this warranty Limited Two 2 Year Warranty Under this warranty Sherwood Industries Ltd covers Ignitor Auger Motor Circuit Board Timers Temp Sensors Blowers Vacu...

Страница 30: ...ify the Limited Warranty on this stove If unsure as to the extent of this Limited Warranty contact your authorized Enviro dealer before installation 10 Sherwood Industries Ltd will not be responsible...

Страница 31: ...vered per our warranty service fee reimbursement schedule Labour rates are set per component and as such total labour costs may not be covered 27 Sherwood Industries Ltd is not liable for freight or l...

Страница 32: ...AL NUMBER ___________________________ DATE OF PURCHASE _____________ dd mm yyyy DATE OF INSTALLATION ___________ dd mm yyyy MAGNEHELIC AT INSTALL ___________________ INSTALLER S SIGNATURE ____________...

Отзывы: