Приобретите удивительный продукт J.A. Roby Mystere и скачайте бесплатный руководство для владельцев, чтобы узнать все его функции и возможности. Не забудьте загрузить его с нашего сайта manualshive.com. Спешите получить свой экземпляр!
1
OWNER’S MANUAL
MYSTERE WITH OR WITHOUT OVEN
March 9th, 2009 Reviewed
MYSTERE
wood burning stove
490, rue de l'Argon, Quebec, Qc CANADA (Québec) G2N 2C9
Phone: 418-849-8095 Fax : 418-849-0077
www.jaroby.com
CAN/ULC S627-M00
UL 1482
Страница 1: ...NUAL MYSTERE WITH OR WITHOUT OVEN March 9th 2009 Reviewed MYSTERE wood burning stove 490 rue de l Argon Quebec Qc CANADA Qu bec G2N 2C9 Phone 418 849 8095 Fax 418 849 0077 www jaroby com CAN ULC S627...
Страница 2: ...INSIDE A MASONRY CHIMNEY 9 EXTERIOR VERTICAL INSTALLATION 9 VERTICAL INSTALLATION ON A CATHEDRAL ROOF 10 CROSS STYLE INSTALLATION 10 VERTICAL INSTALLATION 11 CLEARANCES 12 SEATING 13 FIREBRICKS 13 FAN...
Страница 3: ...IFIED TECHNICIAN AND IN CONFORMITY WITH THE OWNER S MANUAL GUIDE GIVEN WITH THIS APPLIANCE THE INSTALLATION MUST BE IN AGREEMENT WITH LOCAL AND NATIONAL REGULATIONS APPLICABLE FOR SOLID FUEL BURNING A...
Страница 4: ...a minimum of 64 ft2 and must be very well ventilated Minimum clearances found in this manual must be observed Never use a non isolated exterior conduct or a single wall flue pipe as an exterior exit P...
Страница 5: ...e knowledge of the procedure to be followed in case of a chimney fire Think of an emergency plan In case of a chimney fire Hermetically close the doors and the air intakes Water the combustible materi...
Страница 6: ...light smoke is released from the paint during the first hours of use Even if this nuisance is temporary open the windows and the doors in order to ensure a good ventilation This special paint is conce...
Страница 7: ...7m Exterior height 46 116 8cm 31 78 7cm Exterior width 26 66cm 26 66cm Exterior depth 27 70 5cm 27 70 5cm Door opening 17 X 9 44 5cm X 24 1cm 17 X 9 44 5cm X 24 1cm Interior height 12 30 5cm 12 30 5cm...
Страница 8: ...e heat loss with an insulated lining The chimney has to be installed with a stainless steel lining Make sure that all smoke pipe joints are really airtight A leak reduces the efficiency of the applian...
Страница 9: ...l laws or the ULC S635 ULC S640 NFPA211 USA norms Install the chimney following the manufacturer s instructions EXTERIOR VERTICAL INSTALLATION The Mystere wood appliance must be installed in accordanc...
Страница 10: ...ocal laws or the CAN CSA B365 NFPA211 USA norms Install the chimney following the manufacturer s instructions CROSS STYLE INSTALLATION The Mystere wood appliance must be installed in accordance with t...
Страница 11: ...ICAL INSTALLATION The Mystere wood appliance must be installed in accordance with the applicable local laws or the CAN CSA B365 NFPA211 USA norms Install the chimney following the manufacturer s instr...
Страница 12: ...ance only needs 8 inches clearance at its back and 12 inches from the lateral walls when installed with a single wall pipe and a certified CAN ULC S641 heat shield CLEARANCES FROM COMBUSTIBLE MATERIAL...
Страница 13: ...hes at the back Use only non combustible materials such as ceramics marble or granite FIREBRICKS Place the firebricks as illustrated They are identified by the letters A to H and the seal cap is ident...
Страница 14: ...liance is in function the heat reaching a temperature of 120oF activates the thermo disc At this moment the thermo disc activates the fans for a better distribution of heat in your home As soon as the...
Страница 15: ...nce until you know at which frequency it must be cleaned minimum once per year Remove every creosote deposit in order to prevent chimney fires The cleaning of the heat exchanger of the chimney flue pi...
Страница 16: ...eal cords are damaged If so replace them by a inch ceramics cord and replace the broken glasses by VITROCERAMICS glasses of 5mm Cut the glass edge 3mm smaller on each side so that the asbestos cord ca...
Страница 17: ...urer may at its discretion decide to repair or replace any part or unit after inspection and investigation of the defect The manufacturer may at its discretion fully discharge all obligations with res...