Now  that  you  have  completed  the  installation  of  the  appliance  according  to  the 
recommendations, you are ready for the lighting! 
 
1. 

Place papers and small wood in the appliance. 

 
2. 

Before lighting, be sure that the chimney is warm enough. 

 
3. 

When  the  fire  is  well  lit,  gradually  add  bigger  wood  logs  until  an  ember  bed  is 
formed. 

 
4. 

You  can  then  control  combustion  by  closing  or  opening  the  air  intakes  (a  rod 
pulled down indicates a closed air intake). The wood will burn more quickly if the 
air intakes are opened to the maximum and more slowly if they are only slightly 
open. 

 

Do not charge the appliance beyond the bricks

PREVENTIVE MEASURES AND MAINTENANCE 

 
We recommend to open the air intakes completely and to maintain an intense fire from 10 
to 20 minutes per day. 
 
Verify  the  accumulation  of  creosote  every  week  that  you  use  the  appliance  until  you 
know  at  which  frequency  it  must  be  cleaned  (minimum  once  per  year).  Remove  every 
creosote deposit in order to prevent chimney fires. 
 
The  cleaning  of  the  heat  exchanger,  of  the  chimney  flue  pipe  and  of  the  pulling  fan,  if 
necessary, is particularly important at the end of each winter season in order to reduce the 
corrosion  made  during  the  summer  months  and  caused  by  the  accumulation  of  ashes 
(they  must  always  be  in  good  condition.)  To  clean  the  heat  exchanger,  remove  the  top 
bricks, clean them and then replace the bricks at their place. Do not remove the stainless 
steel pipes.

 

 
Do not alter or modify the air intakes of the appliance in order to get a stronger fire. 
 
To clean the glasses, J.A. Roby Inc. recommends using products sold for this purpose or 
an oven cleaner. Avoid cleaning with abrasives or when the glass is hot. 
 
The  Mystere  wood  appliance  is  provided  with  an  ashtray  under  the  door.  To  empty  it, 
remove the steel cap (in the middle of the appliance) and glide the ashes into the ashtray. 
Do not forget to replace the steel cap.  
 

Содержание Mystere

Страница 1: ...NUAL MYSTERE WITH OR WITHOUT OVEN March 9th 2009 Reviewed MYSTERE wood burning stove 490 rue de l Argon Quebec Qc CANADA Qu bec G2N 2C9 Phone 418 849 8095 Fax 418 849 0077 www jaroby com CAN ULC S627...

Страница 2: ...INSIDE A MASONRY CHIMNEY 9 EXTERIOR VERTICAL INSTALLATION 9 VERTICAL INSTALLATION ON A CATHEDRAL ROOF 10 CROSS STYLE INSTALLATION 10 VERTICAL INSTALLATION 11 CLEARANCES 12 SEATING 13 FIREBRICKS 13 FAN...

Страница 3: ...IFIED TECHNICIAN AND IN CONFORMITY WITH THE OWNER S MANUAL GUIDE GIVEN WITH THIS APPLIANCE THE INSTALLATION MUST BE IN AGREEMENT WITH LOCAL AND NATIONAL REGULATIONS APPLICABLE FOR SOLID FUEL BURNING A...

Страница 4: ...a minimum of 64 ft2 and must be very well ventilated Minimum clearances found in this manual must be observed Never use a non isolated exterior conduct or a single wall flue pipe as an exterior exit P...

Страница 5: ...e knowledge of the procedure to be followed in case of a chimney fire Think of an emergency plan In case of a chimney fire Hermetically close the doors and the air intakes Water the combustible materi...

Страница 6: ...light smoke is released from the paint during the first hours of use Even if this nuisance is temporary open the windows and the doors in order to ensure a good ventilation This special paint is conce...

Страница 7: ...7m Exterior height 46 116 8cm 31 78 7cm Exterior width 26 66cm 26 66cm Exterior depth 27 70 5cm 27 70 5cm Door opening 17 X 9 44 5cm X 24 1cm 17 X 9 44 5cm X 24 1cm Interior height 12 30 5cm 12 30 5cm...

Страница 8: ...e heat loss with an insulated lining The chimney has to be installed with a stainless steel lining Make sure that all smoke pipe joints are really airtight A leak reduces the efficiency of the applian...

Страница 9: ...l laws or the ULC S635 ULC S640 NFPA211 USA norms Install the chimney following the manufacturer s instructions EXTERIOR VERTICAL INSTALLATION The Mystere wood appliance must be installed in accordanc...

Страница 10: ...ocal laws or the CAN CSA B365 NFPA211 USA norms Install the chimney following the manufacturer s instructions CROSS STYLE INSTALLATION The Mystere wood appliance must be installed in accordance with t...

Страница 11: ...ICAL INSTALLATION The Mystere wood appliance must be installed in accordance with the applicable local laws or the CAN CSA B365 NFPA211 USA norms Install the chimney following the manufacturer s instr...

Страница 12: ...ance only needs 8 inches clearance at its back and 12 inches from the lateral walls when installed with a single wall pipe and a certified CAN ULC S641 heat shield CLEARANCES FROM COMBUSTIBLE MATERIAL...

Страница 13: ...hes at the back Use only non combustible materials such as ceramics marble or granite FIREBRICKS Place the firebricks as illustrated They are identified by the letters A to H and the seal cap is ident...

Страница 14: ...liance is in function the heat reaching a temperature of 120oF activates the thermo disc At this moment the thermo disc activates the fans for a better distribution of heat in your home As soon as the...

Страница 15: ...nce until you know at which frequency it must be cleaned minimum once per year Remove every creosote deposit in order to prevent chimney fires The cleaning of the heat exchanger of the chimney flue pi...

Страница 16: ...eal cords are damaged If so replace them by a inch ceramics cord and replace the broken glasses by VITROCERAMICS glasses of 5mm Cut the glass edge 3mm smaller on each side so that the asbestos cord ca...

Страница 17: ...urer may at its discretion decide to repair or replace any part or unit after inspection and investigation of the defect The manufacturer may at its discretion fully discharge all obligations with res...

Страница 18: ...18...

Отзывы: