Ash Drawer

5

/

16

" Hex Head 

Screws x4

5

/

8

" Snap Plug x2

Installation

d

eciding

 W

here

 

to

 l

ocate

 

your

 p

ellet

 a

ppliance

:

1. Do not install the stove in a bedroom or room where people sleep in.
2. Locate the stove in a large and open room that is centrally located in the house.  This will optimize 

heat circulation. 

3. Check clearances to combustibles and for the least amount of interference to house framing, plumbing, 

wiring, etc.

4. You can vent the stove with approved pipe through an exterior wall behind the unit or pass it through 

the ceiling and roof.  The stove can connect  to an existing masonry or metal chimney (must be lined 

if the chimney is over 6” (15 cm) diameter, or over 28 inches² (180 cm²) cross sectional area).  

5. This unit must not be installed directly onto carpet. If it is to be installed on a carpeted area, a solid 

surface (wood, metal or approved hearth pad) must be installed between the unit and the carpet.

6. This  unit  uses  large  quantities  of  air  for  combustion;  outside  Fresh  Air  connection  is 

strongly 

recommended

. Fresh Air 

must

 be connected to all units installed in Mobile and “Air Tight Homes” 

(R2000) or where required by local codes.

7.  Do not obtain combustion air from an attic, garage or any unventilated space.  Combustion air may be 

obtained from a ventilated crawlspace. 

8. The power cord is 8 feet (2.43 m) long and may require a grounded extension cord to reach the 

nearest electrical outlet.

r

emoving

 p

ellet

 S

tove

 f

rom

 p

allet

:

1. Open ash pan door 

and  remove  ash 

pan.

2. Remove  the  two 

(2) screws from the 

rear pedestal.

3. Remove  the  plugs 

from the inner front 

of the pedestal.

4. Remove  the  two 

(2) 

5

/

16

”  hex  head 

screws  from  inside 

the pedestal.

5. Re-install the plugs 

into the pedestal.

Figure 3: Screws to take out to remove stove from pallet. 

Содержание M-55-FS

Страница 1: ...CE TECHNICAL MANUAL PELLET STOVE M 55 FS PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF THIS PELLET BURNING ROOM HEATER FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN PROPERTY DAM...

Страница 2: ...aust And Fresh Air Intake Locations 10 Mobile Home Installation 11 Corner Through Wall Installation 11 Horizontal Exhaust Through Wall Installation 12 RECOMMENDED Through Wall With Vertical Rise and H...

Страница 3: ...not operate the stove again until you are certain the chimney and its lining have not been damaged OPERATION The door and ash drawer must be kept closed when the unit is in operation to prevent fume s...

Страница 4: ...bearing capacity if existing construction doesn t meet load capacity suitable measures e g load distributing plate must be taken to achieve it DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYST...

Страница 5: ...tection in front of and to the sides of the door opening Serial No No De Seri To Start Stove Select fuel type mode PREMIUM PELLETS for superior quality pellet fuel REGULAR PELLETS for all grades of wo...

Страница 6: ...ble 1 M 55 FS Specifications Description Fuel type Residential Pellet Heater 6mm dia Pellets wood corn wheat barley Voltage Current Max Power 110 120 V 4 2 Amps 504 Watts Frequency Hopper Capacity Con...

Страница 7: ...is to be installed on a carpeted area a solid surface wood metal or approved hearth pad must be installed between the unit and the carpet 6 This unit uses large quantities of air for combustion outsid...

Страница 8: ...a location that is not too close to the unit but will effectively heat the desired area 2 Connect the Thermostat or Timer using a 2 x 18 gauge wire from the unit to the thermostat If the heat in the...

Страница 9: ...rmination locations Table 2 Use in conjunction with Figure 7 for allowable exterior vent termination locations Letter Minimum Clearance Description A 24 in 61 cm Above grass top of plants wood or any...

Страница 10: ...irtight homes and mobile homes When connecting to an outside fresh air source do not use plastic or combustible pipe A 3 minimum 76 mm ID inside diameter steel aluminum or copper pipe or ducting shoul...

Страница 11: ...heater to the floor using the four 4 holes in the pedestal Ensure the unit is electrically grounded to the chassis of your home permanently Do not install in a room people sleep in Outside fresh air i...

Страница 12: ...fastened with at least three 3 screws 1 Place the appliance 15 37 5 cm away from the wall If the stove will be installed a hearth pad set the unit on it 2 Locate the center of the exhaust pipe on the...

Страница 13: ...installations have 3 to 5 feet 91 to 152 cm of vertical pipe in the system to help naturally draft the unit in the event of extreme weather or a power outage Some horizontal through wall installations...

Страница 14: ...Vertical section of vent pipe Horizontal frame for thimble 90o elbow Concrete Wall Clean out tee Installation to use if there is a concrete or retaining wall in line with exhaust vent on pellet stove...

Страница 15: ...Installations section and then finish it by performing the following refer to Figure 16 1 Install a tee with clean out on the outside of the house 2 Install PL vent upward from the tee Make sure that...

Страница 16: ...o when the pellet vent is installed vertically it will meet the minimum clearance from a combustible wall stated by the vent manufacturer 2 Install the tee with clean out 3 Install the pellet vent upw...

Страница 17: ...chimney If holes already exist fresh air intake can be taken through back of the fireplace or through the ash dump Installation Hearth Mount Installation Figure 18 Hearth Mount Side View Figure 19 He...

Страница 18: ...etting The reading can be taken from the hole located on the Unit s lower left Pedestal Side Note The slider screw is tightened at the factory to holding the slider fully open DO NOT ADJUST If after l...

Страница 19: ...or If the 3 light is flashing unit may be out of fuel Check the Door and Ash Pan door THEY MUST BE CLOSED TIGHT See section 8 The Fuel will not light Check the fuse on the circuit board If the unit st...

Страница 20: ...the ON OFF button 5 Unit is on but auger motor does not turn at all Check the line fuse to see if it has blown Check the Door and Ash Pan door THEY MUST BE CLOSED TIGHT If the Auger gear box does not...

Страница 21: ...eaves fresh unburned fuel in the burn pot liner the fire is going out before the stove shuts off Trim the combustion air down to decrease the magnahelic pressure Turn the Heat Level up slightly poor q...

Страница 22: ...e Purple White Convection Blower Agitator Motor Grey Grey Orange Orange White Grey Grey White Blue Yellow Auger Motor White Yellow Vacuum Switch Connect Thermostat Here Brown Brown Blue Purple Yellow...

Страница 23: ...Coupler 50 1697 6 Convection Blower 80mm 50 2064 7 Enviro Gel Decal 50 322 8 Auger With Paddles 50 1161 9 Ignitor Coil Type 400 Watt 50 1691 10 Auger Stops Clear Rubber 50 1559 11 Auger Plate And Bush...

Страница 24: ...nge Set of 2 50 2047 39 Exhaust Starter Tube Including Gasket 50 2043 40 Auger Tube Cover 50 1410 41 Hopper Lid Including Hinge 50 2037 42 Firebox Top 50 2040 43 Agitator Drive Bracket 50 2038 44 Cast...

Страница 25: ...25 Parts Diagram Components 27 1 2 3 4 5 6 7 8 9 10 12 13 11 14 15 16 17 18 19 22 21 20 25 24 23 26...

Страница 26: ...Parts Diagram Steel 26 55 56 57 58 34 35 47 40 33 32 31 30 29 28 54 51 52 53 49 50 48 46 44 41 45 43 42 39 36 37 38...

Страница 27: ...estrictions and exclusions apply to this warranty Limited Two 2 Year Warranty Under this warranty Sherwood Industries Ltd covers Ignitor Auger Motor Circuit Board Timers Temp Sensors Blowers Vacuum Sw...

Страница 28: ...ify the Limited Warranty on this stove If unsure as to the extent of this Limited Warranty contact your authorized Enviro dealer before installation 10 Sherwood Industries Ltd will not be responsible...

Страница 29: ...vered per our warranty service fee reimbursement schedule Labour rates are set per component and as such total labour costs may not be covered 27 Sherwood Industries Ltd is not liable for freight or l...

Страница 30: ...AL NUMBER ___________________________ DATE OF PURCHASE _____________ dd mm yyyy DATE OF INSTALLATION ___________ dd mm yyyy MAGNEHELIC AT INSTALL ___________________ INSTALLER S SIGNATURE ____________...

Отзывы: