17
Existing Fireplace
Clean Out Tee
Fireplace Damper
Location
Rain Cap
Seal Plate
Vent Pipe (single wall
stainless flex pipe or
PL vent)
Existing Masonary
Flue
Flexible Vent Connector
(Use this 5 ft section of
pipe to vent past fireplace
damper or smoke shelf)
Floor
Protection
Combustible Floor
Masonry Fireplace
Min (6")
150mm
Mantel
Minimum (8") 200mm
from top of stove
Damper Removed
or Fastened Open
Clean-out tee
Fresh-air intake should com
from chimney. If holes
already exist fresh-air intake
can be taken through back
of the fireplace or through
the ash dump.
Installation
h
earth
m
ount
i
nStallation
:
Figure 18: Hearth Mount - Side View.
Figure 19: Hearth Mount - Over View.
1. Lock fireplace damper in the open position.
2. Install flexible stainless steel liner or listed
pellet vent to the top of the chimney. All
joints in the exhaust venting system must
be fastened with at least three (3) screws.
3. Install a sealing plate at the top of the
chimney.
4. Connect a rain cap and flex adapter to the
chimney liner/pipe.
5. Connect a clean-out tee or a 90° elbow to
the liner/pipe.
6. Install tee onto stove.