Wall framing
Wall thimble
Termination cap
Vertical section
of vent pipe
Clean
out tee
Wall strap
90°elbow
Horizontal
frame for
thimble
Installation
recommended
- t
hrough
W
all
W
ith
v
ertical
r
iSe
and
h
orizontal
t
ermination
i
nStallation
:
Figure 14: Venting horizontally with rise.
t
hrough
c
oncrete
W
all
W
ith
v
ertical
r
iSe
i
nStallationS
:
Wall framing
Wall thimble
Termination cap
Vertical section
of vent pipe
Horizontal frame
for thimble
90
o
elbow
Concrete Wall
Clean out tee
Installation to use if there is a concrete or
retaining wall in line with exhaust vent on
pellet stove.
A 45° down elbow with a screen may be used
in place of the termination cap (or stainless
steel termination hood).
The termination must be 12 inches (30 cm)
from the outside wall and 12 inches (30 cm)
above the ground.
Figure 15: Venting with concrete wall behind unit .
A 45° down elbow with a screen may be used in
place of the termination cap (or stainless steel
termination hood).
14