14
Scenario #2
2. i
GniTer
w
ire
is
l
oose
/d
isconnecTed
/s
horTed
Switch to “OFF”
Wait 5 seconds
Switch to “ON”
Light blinks red three times means
igniter lead is disconnected/loose
Check continuity of
igniter wire
Switch the control module to “OFF”, wait 5 seconds, then switch to “ON”� If the diagnostic light
blinks red three times then goes into lockout mode (red/green flashing light), the igniter wire may
be loose or disconnected� Ensure the connection between the igniter wire and the control module�
See Figure 17 below for locations of wire connection to control module�
If the igniter attempts to light for 60 seconds before the module times out, flashes a green light
three times, and goes into lockout mode, the igniter may be shorted� A short in the system could
cause damage to the module�
Figure 17: Control Module - Loose or Disconnected Igniter Wire