5
System Basics
Gas Flow
Gas to Burner
Pilot Out
Pilot In
AUX1 HOT
AUX1 NEUT
AUX2 HOT
AUX2 NEUT
MH3V Gas Valve
8K1N Ignition Control Module
AUX300 – Auxiliary Control Module
Flame Sensor
EV2
EV1
GND
Battery (+)
Battery (-)
Battery Pack (4 X AA)
6VDC Power Supply
RC300
Remote Control
Dexen 8K1N - Complete IPI System
Wall Switch
(Unused)
FAN
AUX1
[EMBER LIGHTS]
AUX2
[TOP LIGHT(S)/POWER VENT]
Spark Ignition
1
2
3
1� ON/OFF/REMOTE switch on module must be in REMOTE position for wireless remote control to
work�
2� The control module communicates to and from the remote control via radio frequency� They
must remain within 30 feet of each other� When in thermostat mode, signal transmission occurs
60 seconds�
AUX300 Module controls the comfort fan with an incorporated timer and rheostat� The AUX300
module also controls the two possible auxiliary functions: AUX1 - Ember Lights and AUX2 - Top
Lights/Power Vent*� Both of these auxiliary functions are unit dependent�
*Note - If use of Power Vent is desired, a separate PVI control module must be acquired (50-4161)�