12
Scenario #1
8. f
aUlTy
m
odUle
Switch the control module to “OFF”, wait 5 seconds, then switch to “ON”� If the diagnostic light
blinks red twice then goes into lockout mode (red/green flashing light), there is insufficient voltage
from the ignition coil to the pilot flame ignitor� The control module will need to be replaced�
Switch to “OFF”
Wait 5 seconds
Switch to “ON”
Light blinks red twice means insufficient
voltage from ignition coil to pilot flame igniter
Figure 14: Fuel Setting Switch
7. f
Uel
s
eTTinG
s
wiTch
on
m
odUle
d
amaGed
or
n
oT
f
Ully
e
nGaGed
LP
NG
Check that the fuel setting switch is not damaged and that it is properly engaged to the correct set-
ting� See Figure 13 & Figure 14 below�
Lift face plate using small flathead screwdriver
Figure 13: Control Module - Fuel Setting Switch
Location
Figure 15: Control Module - Check Power