22
Scenario #5
2. f
aUlTy
V
alVe
(b
Urner
s
olenoid
)
Pilot Solenoid
Should read
between 37 to 47
Burner Solenoid
Should read
between 55 to 65
To check the pilot and burner solenoids, disconnect the wires from the valve� Adjust the multi-meter
to read Ohms and measure the resistance between the pilot/burner solenoid and the body of the
valve� Refer to Figure 26 for probe locations and approximate readings of the multi-meter�
Figure 26: Dexen Valve - Pilot & Burner Solenoid
Scenario #6
p
roblem
: p
ower
oUTaGe
,
fireplace
will
noT
TUrn
on
In the event of a power outage the fireplace should remain operational via the 4 x AA battery
backup� Note, during a power outage AUX1, AUX2 and Fan functions will not be operational�
Possible Causes:
1. l
oss
of
remoTe
siGnal
When the fireplace looses power while in operation it may not automatically turn back on even
though the remote will still be ON� Press the power button on the remote once to turn it off then
again to turn the fireplace back ON�
2. d
ead
b
aTTeries
Remove the batteries from the battery holder and check the voltages with a multi-meter� Confirm
each battery is outputting 1�4 - 1�5 VDC� If measured voltage is lower, replace with new batteries�
3. b
lown
b
aTTery
f
Use
Open the in-line fuse holder on the battery backup and remove the glass fuse� Visually inspect the
fuse and check for continuity using a multimeter� Replace if blown / faulty�
Figure 27: Battery Backup - Fuse
1A Glass Fuse
5mm x 20mm (M205)