Accessories available for use with the EA800 Environmental Alarm System are listed below.
Wired Water Presence Sensor:
2-wire; maximum 304 m (1000 ft.) cabling length
Wired 4-20mA Sensor
EA800 load (160 Ohms maximum)
Relay Outputs
(9) Form C with 3-terminal NC/COM/NO connections.
Note:
There are 8 primary relays (1 dedicated for each sensor) and
1 auxiliary relay.
Relay Contact Ratings
Max 30VDC @ 1 amp resistive.
Not for use with AC power.
Relay Logic
Each relay is user configurable.
Display
128x64 graphic LCD, with blue backlight
Device Environmental Operating Range:
Humidity:
5 to 95% RH, non-condensing
Temperature, Operating:
0°C to 50°C (32° F to 122° F). Not for installation inside coolers or freezers.
Ambient Environmental Quality: Indoor use intended, non-corrosive environment
Conformity Certifications
FCC Part 15, Subpart C, Class B
ICES-003, Issue 3; 1997
NRTL CUE certification mark
Warranty
Two (2) Year Limited Warranty. See Warranty and Service Information.
Notes:
1. Where required, this equipment is to be isolated from the mains supply by a limited power source as specified
in EN60950.
2. All terminals must be connected to a Class 2 Power Limited Circuit complying with the National Electric Code
NFPA 70, Article 725.
3. See “Specifications” on page 46 for power supply requirements.
Table 15
Accessories
Item (Winland Part Number)
Description
BZ-3
: Audible alarm module
(PN 1183)
Buzzer for connection to auxiliary relay output that provides audible alarm
indication.
Power supply (transformer)
(PN L-020-0085)
Regulated 110 VAC-to-12 VDC @ >500 mA (minimum) transformer suitable for
use with EA800.
Note:
Power supply must be a limited power source per notes 1 and 2 in
Table 14.
Table 14
Specifications — continued
Item
Specification
Содержание Alert EA800
Страница 1: ...D 011 0152 Electronic Multi Zone Environmental Alarm System Installation Owner s Manual ...
Страница 20: ...16 D 011 0152 Relay Operation ...
Страница 74: ...70 D 011 0152 Exporting the Stored Logs ...
Страница 81: ...Appendix A Screen Maps D 011 0152 77 Figure 19 Sensors Screen Map See Figure 20 See Figure 21 ...
Страница 84: ...80 D 011 0152 Figure 23 Data Log Screen Map ...
Страница 85: ...Appendix A Screen Maps D 011 0152 81 Figure 24 System Screen Map Dependent on format See Figure 25 ...
Страница 86: ...82 D 011 0152 Figure 25 Configuration Screen Map ...
Страница 88: ...84 D 011 0152 ...
Страница 90: ...86 D 011 0152 ...
Страница 96: ...92 D 011 0152 ...