17
The flue collar is removable for installations
into fireplaces with low openings
.
a)
Remove the rear two (2) secondary
air tube and C-Cast Ceramic Baffles,
if installed (see
C-C
AST
C
ERAMIC
B
AFFLE
I
NSTALLATION
)
. Remove the secondary air
tubes by placing a screwdriver (any style
except flat head) into one of the air holes
and tapping it with a hammer/mallet to
the left.
b)
Unscrew the two (2) nuts on top of the
inside of the firebox, using a
9
/
16
” wrench
or socket (see Figure 13). The Flue Collar
Clamps will slide off the bolts.
c)
Pull the removable flue collar off the top
of the unit.
d)
Attach the flue collar to the venting pipe
using sheet metal screws.
e)
Push the unit into place while trying to
keep the collar attached to venting close
to the opening on the top of the unit.
Combustible Floor
Masonry Fireplace
USA 16” (406 mm)
CND 18” (450 mm)
1" (25mm)
Non-Combustible Board (K 0.84)
Figure 12: Insert Installation into existing floor level
masonry fireplace.
Installation
Floor Protection
Combustible Floor
Masonry Fireplace
8"
(203 mm)
USA 16” (406 mm)
CND 18” (450 mm)
Figure 11: Insert Installation into existing fireplace without
hearth.
f)
Place the Collar Puller, over the two bolts of the Flue
Collar and pull it into place (see Figure 14). Ensure that
the bolts are to the left and right of the hole. If they are
not, the front secondary air tube will need to be removed
in order to install or remove the C-Cast Ceramic Baffles.
g)
Slide the Flue Collar Clamps and washers over the bolts,
and screw the nuts back onto the bolts.
h)
Re-install C-Cast Ceramic Baffles and the rear two
(2) secondary air tube (see
C-C
AST
C
ERAMIC
B
AFFLE
I
NSTALLATION
)
.
3.
There are four (4) leveling legs (shown in Figure 15), two
(2) on each side, one at the back and one at the front of the
unit. Adjust the legs using a 3⁄8” wrench to ensure the unit is
stable.
Figure 13: Attaching removable flue collar.
Firebox Top
Cut-away
Vent pipe
Removable
Flue Collar
Collar Puller
Gasket
Flue Collar Clamp
Washer
Nut