9 Maintenance
STACK 602
10
(PC-000848-MA Issue 5, December 2021)
ENVEA
UK Ltd
1.3
Safety Procedures
Always observe the following safety precautions. Personnel installing, operating,
or maintaining the equipment are responsible for their personal safety and the
correct handling and use of the equipment in accordance with the safety pro
-
cedures detailed in this manual.
Follow all warnings and instructions marked on the product and in this manual.
These safety instructions must be followed to avoid possible personal injury, injury
to others, and damage to the product.
If the equipment is used in a manner not specified in this manual, the protection
provided by the equipment may be impaired. Retain these instructions in a safe
and known place for future use.
WARNING!
Risk of personal injury or injury to others. All personnel must be fully
trained and adhere to local and, where applicable, site-specific health
and safety laws and guidelines.
–
It is the responsibility of the local
organisations to enforce safe working practices at all times
.
WARNING!
–
ELECTRIC SHOCK
Only connect to an earthed supply. The control unit is a Class 1
construction and must be connected to a protective earth connection
(GND).
WARNING!
–
ELECTRIC SHOCK
This product must be connected to a power supply of the same voltage
(V) and frequency (Hz) as indicated on the product rating plate and
provided in the
A supply cable with an adequate rating must be used. Temperature
de-rating must be considered.
CAUTION!
Position the equipment to avoid excessive heat, vibration, humidity,
and dust.
CAUTION!
Failure to service or maintain the product, fitting non-approved parts
or carrying out non-approved alterations or servicing can be dangerous
and could affect the product's safety. It may also invalidate the terms
and conditions of the product warranty.
1.4
Intended Use
The STACK 602 particulate measurement sensor with
DynamicOpacity
®
technology is suitable for measurement in non-condensing applications, such as
electrostatic precipitators (ESPs), boilers, calciners, and large-diameter emission
stacks where dust levels are typically above 10 mg/m³ (and up to 1,000 mg/m³),
including processes that reach temperatures up to 600 °C (1,112 °F).
Limits of Use