5
Material
Base flange
p
Securing ring
Sensor
2. Function
The M-Sens WR3 sensor functionality is based on precise high-frequency measurement and
direct digitalization of measured values, where from results a high resolution. As the material
surface and capillary moisture influences strongly its specific conductive capacity, the moisture
can be measured exactly by a constant averaged bulk density.
The calibration can be done very simply by the operator by pressing the button and entering
the referenced moisture contents.
In this context it is convenient that measured value fluctuations by bulk density variations are
balanced by an internal filter function.
Fig. 5: Injection and reflexion of high frequency