28
8.2 Display
The display is touch-sensitive. Available keys are displayed directly in context. When the
measuring system is first started, a query is initiated to select the language and sensor. If no
selection is made, the initialization disappears and the German language with a M-Sens WR3
sensor is selected.
Initialization screen when the Evaluation unit in the
field housing started first time.
Selection of the menu language:
D
eutsch,
E
nglish,
F
rançais
If a language has been selected, the sensor to be
used must be selected.
To be available:
SolidFlow 2.0, Paddy, PicoFlow, MaxxFlow HTC,
DensFlow, SpeedFlow 2.0, SlideControl, ProSens,
M-Sens 2, M-Sens 3, M-Sens WR3, AirFlow P.
Afterwards the start page appears.
The start page display the following values:
•
Name “M-Sens WR3”, freely selectable text which
describes the material or the measuring point
•
Measured value, here in % Moisture [ % MST ]
Temperature can also be display, separatly or both
values together.
•
[ I ] key for info
To access the main menu, press and hold any area
of the display for several seconds. The sub-menu
selection appears.
In the menus and input fields, the displayed keys can
be used to browse, select, edit or reject:
•
[ Arrow ]: Scroll down the page, Select an option,
Select a position in the input text
•
[ E ] for ESC: Interrupt the function without
making any changes
•
[
8
]: Select the function or confirm the input
•
[ C ] for Clear: Delete a symbol or number.
Select Language
D
E
F
E
#
$
8
Select sensor
M-Sens WR3
E
Main menu 6.xx
1. Measurement range
2. Calibration
3. Alarm
4. Analog output
#
$
8
M-Sens WR3
21.23
% MST
I