23
IP2251EN
Display
Description
Selections
available
R2 - Adjustment of thrust on obstacles and current - motor 2 [%]
The control panel is fitted with a safety device which, when it de-
tects an obstacle:
- stops the opening movement and, if outside the limit area for de-
tecting obstacles, performs a disengagement operation whose du-
ration can be set with
→
;
- reverses the movement during closure operations outside the
limit area for detecting obstacles;
- stops the movement during closure operations within the limit
area for detecting obstacles.
The limit area for detecting obstacles during opening and closing is
determined by the type of limit switch installed. If there is no limit
switch, it is determined on the basis of the selections
→
and
→
.
00 - Minimum thrust
99 - Maximum thrust
See paragraph 11.2.1
TR - Motor delay time
[s]
Delay time for closure of gate wing 1 in relation to gate wing 2.
00-30 s
10
i
NB: make adjustments gradually and only after performing at least three complete
operations to allow the control panel to be set correctly and detect any friction during
operations.
BA - B
a
si
c adj
u
s
tmen
t
Display
Description
Selections
available
DT - Adjustment of obstacle recognition time [s/100]
10 - Minimum
60 - Maximum
NB: the parameter is adjusted in hundredths of a second.
20
ST - Adjustment of start time [s]
0.5 - Minimum
3.0 - Maximum
2.0
TA - Adjustment of acceleration time during opening [s]
0.5 - Minimum
9.9 - Maximum
See paragraph 11.2.1
TQ - Adjustment of acceleration time during closure [s]
0.5 - Minimum
9.9 - Maximum
See paragraph 11.2.1
VM - Initial movement speed
[V]
00 - Minimum
15 - Maximum
(See paragraph 11.2.1)