20
IP2251EN
11.2.1 Selection of automation type
→
and specific
default settings
AS
Type of
automation
Model
R1-R2
Thrust
on
obsta-
cles and
current
VA -
VC
Speed
during
opening
and
closure
VR
Learning
speed
PO-PC
Ap-
proach
speed
TA
Accel-
eration
time
during
opening
TQ
Accel-
eration
time
during
closure
VM
Ramp
start-up
speed
OBBI3BH
50
24
18
07
2
3
03
ARCBH
70
14
10
06
2
3
03
FACIL3H
50
12
10
05
2
3
03
LUXO3BH-4BH
40
16
12
06
1
2
10
PWR25H
50
18
10
05
2
3
03
PWR35H
50
20
12
06
2
3
03
PWR40H
40
22
15
06
1
2
10
11.3 Second level menu - BC (Basic Configurations)
Display
Description
Selections
available
AC - Enabling of automatic closure
ON - Enabled
1-2 - Dependent on input 1-2
SS - Selection of automation status at start
OP - Open
CL - Closed
Indicates how the control panel considers the automation at the
time of switch-on, or after a POWER RESET command.
SO - Enabling of reversal safety contact functioning
ON - Enabled
OF - Disabled
When enabled (ON) with the automation idle, if the contact 1-8 is open, all
operations are prevented.
When disabled (OF) with the automation idle, if the contact 1-8 is open, opening
operations are permitted.
NI - Enabling of NIO electronic anti-freeze system
ON - Enabled
OF - Disabled
When enabled (ON), it maintains the efficiency of the motor even at low ambi-
ent temperatures.
NB: for correct operation, the control panel must be exposed to the same am-
bient temperature as the motors.
The intervention temperature for NIO can be set by selecting
→
.
BC - B
a
si
c c
o
nfig
u
ra
ti
ons
Содержание LCU30H
Страница 6: ...6 IP2251EN Fig 4 5 Fig 4 3 Fig 4 4 A ...