IP2251EN
Output
Value of
accessories
Description
RDX
6ZENRS
ZENPRS
The control panel is fitted with a housing for modules of the
6ZENRS radio receiver type (433.92 MHz).
Can be replaced with a radio receiver module of the ZENPRS
type (868.35 MHz).
The operating mode is selected via
→
.
When using slot-in radio boards, remove the RDX module.
The display will show
.
WARNING: the modules must be inserted and removed with the
power supply disconnected.
COM
BIXM R2
COM - This allows the functioning configurations to be saved
using the function
→
.
The saved configurations can be recalled using the function
→
.
COM - The storage module allows the remote controls to be
stored. If the control panel is replaced, the storage module being
used can be inserted in the new control panel.
WARNING: the storage module must be inserted and re-
moved with the power supply disconnected, and paying at-
tention to the positioning direction.
BAT
SBU
BAT - Battery-powered operation.
The batteries are kept charged when the power supply is on. If
the power supply is off, the panel is powered by the batteries
until the power is re-establish or until the battery voltage drops
below the safety threshold. The control panel turns off in the
last case. WARNING: the batteries must always be connected to
the control panel for charging. Periodically check the efficiency
of the batteries.
NB: the operating temperature of the rechargeable batteries is
from +5°C to +40°C.
For advanced control of battery-powered operation, refer to
the menu
.
Jumper
Description
OFF
ON
JR1
Display mode selection.
Display mode.
Only the v alue s and pa-
rameters present can be
displayed.
Maintenance mode.
Only the v alue s and pa-
rameters present can be
displayed and modified.
A c t i v a t e d m a i n t e n a n c e
mode is indicated by the
permanent switching on of
the right-hand point on the
display.
10. Jumper setting