81
IP2179EN - 2015-11-24
TOP903H
19. Electrical connections TOP903H
Installation, electrical connections and adjustments must be performed by qualified person-
nel, in accordance with Good Working Methods and in compliance with the current regulations.
The automation must be installed in compliance with Standards EN 12453, EN 12445 and EN
12635.
The safety devices must be working properly.
Garages without a second entrance must be equipped with an external emergency release device
(to be ordered separately).
If there is a pedestrian door incorporated into the garage door, it must be closed and equipped
with a safety device that prevents it being activated when the garage door is open.
This safety
device must be connected to the EMERGENCY STOP input.
1 2 3
16
15
17
10
24V
0V 24V
11 12
4 5
6
N
Courtesy
light
DO NOT USE
Step by step
Antenna
SIG
GND
L PE
Power unit
Electriclock
Power supply
Motor
T
OP905A
C
T
OP905CAB1
T
OP
T
OP905CAB3
F1.6AT electriclock
7
13
14
8 9
F1.6AT line
24V
T
OP905CAB2
T
OP905CAB4
GREEN
YELLOW
In the external automation section, the connections to the mains power supply and any
other low voltage wires (230V) must be made on an independent channel separated from
the connections to the command and safety devices (SELV = Safety Extra Low Voltage).