13.2
Commands TOP603H
13.3 Outputs and accessories TOP603H
Command
Function
Description
18
19
NO
STEP-BY-STEP
The closure of the contact activates a sequential opening or
closing operation: opening-stop-closing-stop.
OPENING
With automatic closure enabled (parameter b4), the closure of
the contact activates an opening operation.
NO
STEP-BY-STEP
The closure of the contact activates a sequential opening or
closing operation: opening-stop-closing-stop.
OPENING
With automatic closure enabled (parameter b4), the closure of
the contact activates an opening operation.
NC
STOP
The opening of the safety contact causes the current move-
ment to stop, and the automatic closure is disabled.
NC
REVERSAL
SAFETY
The opening of the safety contact triggers a reversal of the
movement (reopening) during the closing operation, and the
flashing of the courtesy light.
After the 3rd consecutive reversed movement, the automatic
closure is disabled (if active) and the courtesy light flashes
for about 10 min.
Output
Value - Accessories
Description
24 V / 0.3A for 2s
24 V / 0.08A
continuous
Power supply to accessories.
The maximum continuous absorption refers to all the accessories
installed. Yellow wire (+24V) and black wire (-0V) with TOP905CAB2.
LAMP
230 V~ / 25W
Flashing light (with TOP905AC).
Activated during opening and closing operations.
max 1.6A
Electric lock (with TOP905AC).
Activated for 1s at each start (even with the door open).
1
2
max 230 V~ / 60W
Courtesy light.
Activated for 120s at the end of every operation.
An additional E14 courtesy light can be connected (in parallel) - max
60W or equivalent.
DO NOT CONNECT fluorescent tubular lamps.
NB: some energy-saving lamps may interfere with the radio signal.
20
21
GOL148REA
Antenna
Connect the supplied antenna wire (345mm), or alternatively the
GOL148REA antenna, using an RG58 coaxial cable.
WARNING: make a jumper for all unused NC contacts.
i